Proposed Tech Specs 3.3.3.8 & 4.3.3.8 Re Accident Monitoring Instrumentation Limiting Condition for Operation & Surveillance Requirements,Respectively
ML19331D917
Person / Time
Site: Farley 
Issue date: 09/02/1980
From:
ALABAMA POWER CO.
To:
Shared Package
ML19331D914 List:
References
NUDOCS 8009040251
Download: ML19331D917 (3)


Text

(Q.

s ATTACHMENT 2 Accident Monitoring Instrumentation Limiting Condition For Operation 3.3.3.8 The accident monitoring instrumentation channels shown in Table 3.3-11 shall be OPERABLE.

APPLICABILITY: MODES 1, 2 and 3.

ACTION:

a.

With the number of OPERABLc accident monitoring channels less than the required number of channels shown in Table 3.3-11, either restore the inoperable channel to OPERABLE status within 31 days, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

b.

With the number of OPERABLE accident monitoring channels less than the minimum channels OPERABLE requirements of Table 3.3-11; either restore the inoperable channels to OPERABLE status within 7 days or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.3.3.8 Each accident monitoring instrumentation sSannel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK and CHANNEL CALIBRATION operations at the frequencies shown in Table 4.3-7.

8 0 090 40 'a E l

i TABLE 3.3-11 ACCIDENT HONITORING INSTRUMENTATION REQUIRED MINIMUM NUMBER CHANNELS INSTRUMENT OF CHANNELS OPERABLE 1.

Reactor Coolant Outlet Temperature-T

-Wide Range 2

2 ilot 2.

Reactor Coolant Inlet Temperature-TCold-Wide Range 2

2 3.

Reactor Coolant Pressure-Wide Range 2

2 4.

Steam Generator Water Level-Wide Range or Narrow Range 2 / Steam Generator 1 of 2/ Steam Generator.

5.

Refueling Water 5torage Tank Water Level 2

2 6.

Containment Pressure 2

2 7.

Pressurizer Water Level 2

2 8.

Steam Line Pressure 2 / Steam Generator 2/ Steam Generator 9.

Auxiliary Feedwater Flow Rate 2

2

10. Reactor Coolant System Subcooling Margin Monitor 2

2 1 / Valve 1/ Valve

11. PORY Position Indicator
  • 1 / Valve 1/ Valve
12. PORV Block Valve Position Indicator **

i

13. Safety Valve Position Indicator 1 / Valve 1/ Valve
  • - Not applicable if associated block valve is in the closed position.
    • -- Not applicable if the block valve is verified in the closed position and power is removed.

e i

b

TABLE 4.3-7 ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CilANNEL CHANNEL INSTRUMENT, CHECK CALIBRATION M

R 1.

Reactor Coolant Outlet Temperature-THo t-2.

Reactor Coolant Temperature-TCold-Wide Range M

R 3.

Reactor Coolant Pressure-Wide Range M

R 4.

Steam Generator Water Level-Wide Range or M

R harrow Range 5.

Refueling Water Storage Tank Water Level M

R 6.

Containment Pressure M

R 7.

Pressurizer Water Level M

R 8.

Steam Line Pressure M

R 9.

Auxiliary Feedwater Flow Rate M

R

10. Reactor Coolant System Subcooling M

R Margin Monitor

11. PORY Position Indicator
  • M R

12.

PORV Block Valve Position Indicator **

M R

13.

Safety Valve Position Indicator M

R Not applicable if associated block valve is in the closed position.

Not applicable if block valved verified ir, closed position and power removed.

G' g