~8
[
Table 3 11-1C MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE f
PLANT: Vermont Yankee Fuel Type: 8D274L Average Planar Exposure MAPLHGR PCT 0xidatien (MWD /T)
(KW/ft)
(OF)
Fraction 200.0 11.2 2060.
0.019 1,000.0 11 3 2064 0.019 5,000.0 11.9 2133 0.024 10,000.0 12.1 2129 0.023 15,000.0 12.2 2159 0.025 20,000.0 12.1 2167.
0.026 25,000.0 11.6 2118.
0.023 1
30,000.0 10.9 2028.
0.017 35,000.0 9.9 1896.
0.010
_40,000.0 9.3 1812 0.007 Source:
NEDO-21697, August 1977 (revised) 8008070325-180-o1
_l
Table 3 11-1D I
MAPLNGR VERSUS AVERAGE PLANAR EXPOSURE 4
e
- i PLANT
- Vermont Yankee Fuel Type: 8D274H
+
Average P.lanar l
Exposure MAPLHGR PCT 0xidation (MWD /T)
(KW/ft)
(OF)
Fraction l
200.0 11.1 2052.
0.019 1,000.0 11.2 2050.
0.018 l
5,000.0 11.8 2113 0.022 10,000.0 12.1 2131.
0.023 15,000.0 12.2 2161.
0.026 20,000.0 12.0 2164 0.026 25,000.0 11.5 2112.
0.022 30,000.0 10.9 2029 0.017 35,000.0 10.0 1900.
0.011 40,000.0 93 1815.
0.008 Source:
NEDo-21697, August 1977 (revised) i 180-n2
GENER AL h ELECTRIC
"" ^" "'"'
AND SERVICES CENERAL ELECTRIC COMPANY,175 CURTNER AVE.. SAN JOSE, CALIFORNIA 95125 DlVIS1ON July 16, 1980 NEX: 80-155 Mr. J. W. Heard Vermont Yankee Nuclear Power Corporation 20 Turnpike Road Route 9 Westboro, Massachusetts 01581 Subj ect :
Errata and Addenda Sheets - Number 2 LOCA Analysis Report for Vermont Yankee Nuclear Power Station - NEDO-21697
Reference:
Ltr., BC Slifer to CM Richards, " Extended Exposure MAPLHCRs,"
dtd. July 9, 1980. NED 80-534, VY K.3.3.3
Dear John:
Attached for your use and information are two (2) copies of the subject errata and addenda sheets. This confirms that the extended MAPLHCRs for the 8D274H and 8D274L fuel types were calculated using the approved LOCA models for Vermont Yankee as requested by Mr. Slifer in the referenced letter.
Very truly yours,
,l C. M. Richards, Manager Fuel Projects - Northeast Region M/C 193 - (408) 925-6509 mq Attachments cc:
J. Abbey WF Conway SJ Jefferson, w/att.
VY Document Center c&C'flifer, w/att.
S. Wilkins JL Rash
(.,
(
NUCLEAn ENE AGY BUSINESS GCOUP e GENEf1 AL E LECT'meC COMP ANY SAN JOSE, CALIFORNI A 95125
+
GEN ER AL h ELECTRIC APPLICABLE TO:
NEDO-21697 PUBLICATION NO.
~d ADDENDA 77NED149 5HEET
- r. i. E. NO.
TITLE i')CA Analysis Perert for 2
vamnt v
+a= 9,ci aa* h=*
,varch 1980 e
0,,,
Station NOTE: Correct allcopies of the applicaole AUTSt 19
- UDIICJII#U '# ##### '## # ##
tSSUE DATE REFERENCES INST RUCTIONS eTEM (SECT'ON P'GE tconnEcrioNs AND ADDITIONS)
PAR AG R APH LINE) 1 Pages 4-9 & 4-10 Paplace with new pages 4-9 ard 4-10.
Changes are irdicated by vertical bar in right-ha-d cargin.
aaGE 1 Of 1
( ~ '-
(.
NEDD-21697 Table 4C MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Vermont Yankee Fuel Type:
8D274L Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t)
(kW/ft)_
('F)
Fraction 200.0" 11.2 2060.
0.019 1,000.0 11.2 2064 0.019 5,000,0 11.9 2133.
0.024 10,000.0 12.1 2129.
0.023 15,000.0 12.2 2159.
0.025 20,000.0 12.1 2167.
0.026 25,000.0 11.6 2118.
0.023 30,000.0 10.9 2028.
0.017 35,000.0 9.9 1896.
C.010 40,000.0 9.3 1812.
0.007 T
e 4-9
f' NZDO-21697
/~
(,
(
Table 4D MAPLHGR VERSUS AVERAGE PLANAR EXPOSLE Plant: Vermont Yankee Fuel Type:
80274H Average Planar Exposure MAPLHGR PCT 0xidation CNWd/t)
(kW/ft)
(* F)
Fraction 200.0 11.1 2052.
0.019 1,000.0 11.2 2050.
0.018 5,000.0 11.8 2113.
0.022 10,000.0 12.1 2131.
0.023 15.000.0 12.2 2161.
0.026 20,000.0 12.0 2164 0.026 25',000.0 11.5 2112.
0.022 30,000.0 10.9 2029.
0.017 35,000.0 10.0 1900.
0.011 40,000.0 9.3 1815.
0.008 4-10