Responds to NRC 800724 Telcon Re Criteria for Plugging Condenser Tubes.Procedure FNP-2-AOP-25.0, Condenser Leakage & Table 12 of Procedure FNP-0-CCP-102,revised to Add Feedwater Ph & Cation Conductivity Limits,Encl
ML19330B711
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 07/29/1980
From: Clayton F
ALABAMA POWER CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML19330B712 List:
References
NUDOCS 8008050410
Download: ML19330B711 (3)


Text

.e Alaoam: Power C:mp;ny 600 Nortn 18tn Street Post Office Box 2641 Birmingnam. AiaDama 35291 Telepnone 205 323-5341 k

h L';$fei,";ffe,,

Alabama Power July 29, 1980 re scarem erefre system Docket No. 50-364 Director Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Mr. A. Schwencer RE: Joseph M. Farley Nuclear Plant - Unit 2 Staam Generator Tube Integrity Gentlemen:

In response to the criteria for plugging condenser tubes discussed by conference telephone call with the NRC on July 24, 1980, Alabama Power Company agrees to add feedwater limits on pH and cation conductivity.

Accordingly, Table 12 of Procedure FNP-0-CCP-102, '*4ater Chemistry Specifi-cations", has been revised to reflect the addition of feedwater pH and cation conductivity limits. Also, Procedure FNP-2-A0P-25.0, " Condenser Leakage" has been changed to reflect the additional feedwater limits.

If you have any questions, please advise.

Very truly youn.,

7

'A T

4 cLc c -4 F. L. Clayton, Jrt FLCJr/WMJ:aw Attachments (1) Table 12 of Procedure FNP-0-CCP-102 (2) Procedure FNP-2-A0P-25.0 cc:

Mr. R. A. Thomas Mr. G. F. Trowbridge Mr. W. H. Bradford

'eo/

5 THIS DOCUMENT CONTAINS

/[

POOR QUAUTY PAGES 8 0080 5 0 f/O.

g

d FNP-0-CCP-102-TABLE 12 STEAM GENERATORS /FEEDWATER MODE 1 - NOPNAL Feedwater:

Hydrazine 5 ppb greater than dissolved c:- ;aa concentration (Minimum)

/

Dissolved Oxygen - <5 ppb 2

pH G-25 C - 8.8-9.2 Cation Conductivity <2.0 pmhos/cm 2

Blowdown:

pH @ 25 C - 8.5 - 9.0 Free Hydroxide <0.15 ppm as CACO 3 Cation Conductivity <2.0 uchos/cm 1

1Cross S, y (degassed) - Compare to D.E.1-131 limit I.E. I-131 - <0.10 uC1/ gram 1

D MODE 1 - LIMITING AVT SPECIFICATIONS

}:

Blowdown:

Two Weeks 24 Hours Immediate pH @ 25 C

>9.0<9.4 N/A

<8.5 or >9.4 2

Cation Conductivity vehos/cm @ 25 C

>2.0 but $7 N/A

>7 Free Hydroxide ppm as-CACO 3 N/A

>0.15 but <1.0 21.0 Feedwater:

pH @ 25 C 28.5<8.8 or N/A

<8.5 or >9.4 2

>9.259.4 Cation Conductivity uchos/cm @ 250C

>2.0 but $7 N/A

>7

-MODE 2

~Feedwater:

Hydrazine - 5 ppb greater than dissolved oxygen concentration (Minimum)

. Dissolved oxygen - <100 ppb Table 12 Sheet 1 of 2 2

~Rev. 2

FNP-0-CCP-102 B15wd wn:

pH G 25 C - 8.5 - 10.0 Free Hydroxide - 0.15 ppm as CACO 3 (max.)

Cation Conductivity - 7 umhos/cm (max.)

1 Gross S,y (degassed) - Compare to D.E. !-in limit i

1.E. I-131 - 10.10 uCi/ gram D

MODE 3, 4, and HOT FUNCTIONAL Blowdown:

pH 8.8 to 9.2 G 25 C Free Hydroxide 0.15 ppm as CACO 3 (max.)

Cation Conductivity 2.0 umhos/c= at 25 C (max.)

1Gross 8, y (degassed)

Compare to D.E. I-131 limit 1

.E. I-131 10.10 uCi/ gram D

1 MODE 5, and 6 Blowdown:

pH 10.0 to 10.5 0 25 C Free Hydroxide

'Non-detectable 1

Chloride 0.5 ppa (max.)

.Hydrazine 75 to 150 ppm Dissolved Oxygen 100 ppb (max.)

ILCO - MODES 1, 2, 3, and 4 With the specific activity of the _ secondary coolant system >0.10 uCi/ gram DOSE EQUIVALENT I-131, be in at least HOT STANDBY vithin 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD-SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

2 DEVIATION Deviation from this range may be authorized to control secondary system dissolved oxygen by the sector supervisor (chemistry), provided all limiting AVT specifications are met.

Table 12 Sheet 2 of 2 2

Rev. 2 l