Forwards LER 80-059/01T-0
Date released: 12/10/2019 Download: ML19330A949


LER 80-059/01T-0:on 800710,util Informed by GE That Process Computer Was Not Using Correct Fuel Lengths When Calculating Max Total Peaking Factor.Cause Not Stated.Procedures Revised to Correct Tpf Ref Value
ML19330A954
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 07/25/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19330A954 (1)
Forwards LER 80-059/01T-0
ML19330A948
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 07/25/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19330A948 (2)