,. 3. s N0Y 101989
[
Docket No'.
50-336 Nertheast Nuclear Energy Company.
ATTN:- Mr.. E. J. Mroczka Senior Vice President - Nuclear n
Engineering.and Operations P.' O. Box 270; Hartford, Connecticut 06141-0270 Gentlemen:
Subjecti Enforcement Discretion Regarding Containment Integrity During Inoperability of the Emergency Diesel Generators a
- This letter is in response to your November 9,1989 letter (copy attached) requesting enforcement discretion, and confirms the telephone cuniersation of
' November 10, 1989 between Mr. Jeffrey Smith and other members of'your staff and Mr. Thomas T. Martin and other members of my staff granting your request.
Thisl request was for'one-time enforcement discretion regarding containment.
integrity Fequirements due to the administrative inoperability of the emergency dieselfgenerators that occurred at 6145 p.m. on November 9, when the service
/ water pump. discharge strainers were determined analytically to be not qualified g
'to appropriate-seismic criteria, t.
P Specifically.for.the reasons described in your letter and discussed in that k
telephone conversation, this action grants relief from Millstone 2 Technical SpecificationL3.8.2.2, "A.C. Distribution - Shutdown" requirements to establish L
containment integrity per Technica1' Specification 1.8.2, regarding closure and L
! sealing-of'the containment equipment hatch within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> from the loss of diesel operability.
L
,In lieu of full closure of the hatch, you propose to implement procedures and
' administrative controls that you established in response to Generic Letter 88-17
'" Loss:of Decay Heat Removal" that would assure containment closure within 122 minutos.
It is our understanding that the electrical buses referenced in r
' Technical-Specification 3.8.2.2 will remain energized from sources of power i
t.
tother than a diesel generator and that diesel generator power will remain j
o Lavailable to the buses. This enforcement discretion specifically applies to the alternate method of containment closure and authorizes an extension of the time-the plant may continue with cold shutdown activities without full i
f Jcontainment closure while the diesels are administrative 1y inoperable, j
~
u
+
.l
%t-W i
t i i
0FFICIAL RECORD COPY EDG INOP LETTER - 0001.0.0 e911210131 891110
.s 11/10/89
..(<
PDR ADOCK 05000336 e
P PDC
,b
+
,. ppy y.-
- W a
s
- i "',
~
2
~
NQytg q
.r.
'j-
'Aortheast Nuclear Energy Company 2
,~
^
.This discretion will remain in effect until.5:00 p.m. Tuesday, November 14, 1989, unless'you contact this office before that time and present c
(.
' justification'for an extension.
Sincerely,.
Otiginal Signed By:.
' Thomas T. Martin William T. Russe 11'
> Regional Administrator o
ec-w/ enc 1:
W. D. Romberg, Vice-President, Nuclear Operations S. E..Scace, Station Superinter. dent D. 0.-Nordquist, Director nf Quality Services-R.~ M. Kacich. Manager, Ger.eration Fac',11tias Licensing C. B.: Miller, Station Superintendent,lladdan Neck
. Gerald Garficid, Esquire.
Public Document Room (PDR)-
4, Local Public.Dobument. Room (LPDR)
NurlearSafetyinformationCenter(NSIC)
NRC Resident Inspector j
State of Connecticut i*
1 Y
s t
J OFFICIAL RECORD COPY EDG INOP LETTER - 0002.0.0 11/10/89
)
a
~
w NOV 101999 Northeast Nuclear Energy Company 3
o I
bec w/ enc 1:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o enc 1) i DRP Section Chief J. Shediosky, SRI, Haddam Neck W. Raymond, SRI, Millstone
'O. Jaffe, LPM, NRR J. Dyer, EDO e
e r
i R
Rj' 1:0 P R nA Raymond Haverkamp We v. nger JL%9 i
11//0/89 11//p/89 11//0/89 11/g)/89 11//J /89 0FFICIAL RECORD COPY EDG IN0P LETTER - 0003.0.0 i
11/10/89 i
l