't APPENDIX A NOTICE OF VIOLATION Duquesne Light Company Docket No. 50-334 This refers to the inspection conducted by a representative of the J
Region I (Philadelphia) office at the Beaver Valley Power Station, Unit i
1, Shippingport, Pennsylvania of activities authorized by NRC License No. DPR-66.
During this inspection, conducted January 28-31, and February 1,1980, I
the following apparent item of noncompliance was identified.
10 CFR 50, Appendix B, Criterion V states in part, " Activities affecting quality shall be prescribed by documented instructions, procedures...
and shall be accomplished in accordance with these instructions, procedures Licensee's Maintenance Manual Chapter 1, Conduct of Maintenance, Section J, Housekeeping, revision 4 dated September 10, 1979 states in part, "The entire station will be toured once a month... responsible supervisors
... ensure that all areas are cleaned..."
Contrary to the above, the licensee did not conduct station housekeeping tours during the months of December 1979 and January 1980.
This item is an infraction.
8008060006
.