ML19326C673

From kanterella
Jump to navigation Jump to search
Requests Addl Info to Complete Review of Util 750709,0808 & 22 ECCS Evaluation Submittals.Response Due by 751015
ML19326C673
Person / Time
Site: Arkansas Nuclear 
Issue date: 09/16/1975
From: Ziemann D
Office of Nuclear Reactor Regulation
To: Phillips J
ARKANSAS POWER & LIGHT CO.
References
NUDOCS 8004250489
Download: ML19326C673 (4)


Text

- -

s s.,

e a

DISTRIBUTION:

Docket File ORB #2 Reading DLZiemann SEP 16 gg73 RMDiggs Docket No. 50-313 WConverse NRC PDR Local PDR TBAbernathy Arkansas Power 4 Light Company KRGoller

' TTN: Mr. J. D. Phillips TJCarter A

Senior Vice President OELD Production, Transmission, and OISE (3)

Engineering SVarga Sixth and Pine Streets DElsenhut Pine Bluff, Arkansas 71601 ACRS (16)

Gentlemen:

.v We are reviewing the Arkansas Nuclear One - Unit 1 Emergency Core Cooling System reevaluation submittals dated July 9, 1975, August 8, g

1975, and August 22, 1975, and have concluded that the additional information described in the enclosure is needed to complete our review.

To enable us to maintain our review schedule, please provide the requested additional information by October 15, 1975.

3 Sincerely, Oricinal Signes y.

DennisL.Ziemann/

Dennis L. Ziemann Chief Operating Reactors Branch #2 s

Division of Reactor Licensing

Enclosure:

Roquest for Additional Information THIS DOCUMENT CONTAINS cc w/ enclosure:

See next page POOR QUAUTY PAGES h

RL:0RB#2 pRL: ORB #2 orrmr > _.$,. bb WConverse:ah DLZiemann su m uc>

g

,~

f, u b

[6 [

9/.5/7.5.....

9//O/75 on, Forse AEC.318 gRev. 9-33) AECM 0240 -

ese ess-to-stees-t 44swi7s

p.,

cro 3 3 G75

~

i rkansas Power-& Light Company 2

1

- cc w/cnclosure:

Horace Jewel 1~

- House Holms & Jeueli 4-1550 Tower Building

-Little-Rock, Arkansas ;72201

' Mr. William Cavanaugh, III Production Department Post Office Box 551 Little Rock,. Arkansas.72203

- Arkansas Polytechnic College

' Russellville, Arkansas 72801 f

4 e

a 4

4 en f

i k

- h g

+

4----g-9 wyw',

V AR)MSAS P0hT.R:6 LIGilT CO:.

,Y ARPANSAS NUCLEAR ONE D3CKET NO. 5'0-313 REQUEST FOR ADD)TIONAh INFOR:!ATION The 'ECCS; analysis for your plant is reforcuced to bah'-10103.

Provide justification for the following input paranators used in bah'-10103 by comp irison with the appropriate values for your plant.

. 1. LNet Free Containacnt Volume - Justification should include the total gross internal contain::.cnt voluuc and the internal structures and equip-

~

ment and their volun.cs which are subtracted to obtain the not frec containuent volume.

A discussig,n of the uncertainties should be pro-vided.

. 2.

Passive !! cat Sinks _ - Provide the actual passive heat si.nk st ructures for your plant.

Discusr. the ucthod of detery.ining the passive contain-ment heat ' sinks.

Identify each heat r. ink by category -(i.e., cah]c tray, equipment supports, floor grating, crane wall, etc.) and provide surface area, ' thickness, tatorials.of const ruction, - therna) conductivity and volumetric heat capacity,' by component category used in the containuent :

transient analysis code.

3.

Starting Tine 2cf Containment CoolinpJstem(sl - Discuss the factors

~ hat show that the start tine (s) assuned in the containment response

.t

~

' analysis represent the earliest possible initiation of systeu(s) operation.

4.- Containment Initia1' Conditions - Coir. pare the initial values of-temperature.

pressure"and relative' humidity in the containment with-the range of valt.as that will;be permitted during plant operation.

~

t 1

1

7. _,.

v s

s

~

5.

Containment Spray Water Temperature - Show that the value of containment

_ spray ater temperature used in the containment response analysis is the w

lower bound temperature consistent with plant operating conditions and that the spray flow rate used is suitably conservative.

6.

Fan-Cooler Heat Removal Rate - Compare the maximum fan-cooler heat removal rate for your plant with that assumed in BAN-10103.

Show that minimum operational values of service water temperature have been used.

7.

If any of the above parameters are less conservative for your plant than used in the generic evaluation of BAW-10103, provide the sensitivity of these parameters to the overall containment pressure response. This evaluation should demonstrate the overall conservatism of your contain-ment parametcrs to those used in.BAW-10103.

I