g f'c[
^
^
UMTED STATES f
NUCLEAR REGULATORY COMMISSION g..
. j WASHINGTON, 0. C. 20665
. /
August 22, 1978
.v Docket No.: 50-313 Arkansas Power & Light Company ATTN:
Mr. Willian Cavanaugh, III Executive Director, Generation and Construction Department P. O. Box 551 Little Rock, Arkansas 72203 Gentlemen:
The Commission has issued the enclosed Amendment No. 35 to Facility Operating License No. DPR-51 for Arkansas Nuclear One, Unit No.1.
This amendment consists of changes to the Technical Specifications and is in response to your submittals of September 17, October 5,1976; June 16, July 18, August 30, September 6 and 21, October 26, Decenoer 12 ano 20,1977; and January 12 and 17, Feoruary 3 and 28, March 31, April 12 and 2t,, June 13,15, 21, 29 and 30, and July 7, 14 and 25, 1976.
This amendment,
, a license condition relating to the completion of facility modi :<:ations for fire protection and modifies the Technical Specifications to require at ieast five individuals with fire protection training be on site at all times. The Technical Specifications relating to the fire brigade are effective 90 days from the date of issuance. By letter dated March 3,1976, we issued Technical Specifications to incorporate limiting conditions for oper-ation and surveillance requirements for existing fire protection systems and acministrative controls. You are requested to propose revised Technical Specifications related to facility modifications described herein and submit them for our review no later than 90 days before the implementation dates listed in Table 3.1 of tne enclosed Safety Evaluation. Certain items listed in Section 3.0 of the enclosed Safety Evaluation are markea with an asterick to indicate that the NRC staff will require adoitional information in the fom of design details, test results, or acceptance criteria to assure that the design is acceptacle prior to actual implementation of tnese modifications. Please submit the additional infomation at least 90 days prior to the implementation dates of the modifications.
I g en4180 66 f
m
}
,s Arkansas Power & Light Company.
Copies of the Notice of Is:uance and the report of our fire protection consultants (letter from Robert E. Hall to R. L. Ferguson dated July 11, 1978) are also enclosed.
Sincerely, g ksf k'
'e s Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors
Enclosures:
1.
Amendment No. 35 2.
Safety Evaluation 3.
Notice-4 Consul tant's Report cc w/ enclosures: See next page 1
i
m s
e Arkansas Power & Light Ccapany ec w/ enclosures:
Phillic K. Lyon, Escuire House, Holms % Jewell 1550 Tower Builcing Little Reck, Arkansas 72201 Mr. Daniel H. Willimns Manager,' Licensing Arkansas Power & Light Company Post Of fice Sox 551 Little Rock, Arkansas 72203 Mr. Jonn W. Anderson, Jr.
Pl ant Superintencent Arkansas Nuclear One Post Of fice Sox 608 Russellville, Arkansas 72801 c lytechnic College Arkansas o
Russellville, Arkansas 72501 Honoracle Ermil Grant Acting County Judge of Pace Ccunty Pace County Ccurtnouse
- ussellville, Arkansas 72801 i
Chief, Energy Systems Analyses 3rancn (aW 459)
Office of Radiation Prograns U. S. Environmental Protection Agency Rocn 645. East Tower
' l A01 4 Street, S. 4 4asningt:n, 2. C.
20450 l
l U. 5. Envircecec:al orc ection Agency Recian V* Cf fice A 7', :
E:5 0:090D:A7:R 1201 E'n Street Firs: *nternational Suilcing Callas, Texas 75270 l
ec w/ enclosures 5 inc:nin; d:d:
1/12,
2/3323, 9/17 & 10/5/76; 7/13, S/30 9/5321, 10/25, 12/12520/77:
irec :, :ureau :,,:nvironmenta 3/31,1/12326, 5/13,* 5,21,29&30 and et in Services,
7/7, 7/]4 3 7/33f73 13'5 Wes: "a'kaan : ree:
Little ROOK, tr<ansas 72' '
a
i
,m ATTACHMENT TO LICENSE AMENDMENT NO. 35 FACILITY OPERATING LICENSE NO. DPR 51
}0CKET NO. 50-313 Accomplish page changes to the Appendix A portion of the Technical Specifications as noted below.
The changed areas on the revised page are identified by a marginal line, j
Remove Page Insert Page 118 118 i
<s TABLE 6. 2-1_
ARKANSAS NUCLEAR ONE MINIMUM Sil1FT CREW COMPOSITION #
UNIT 1 COLD AND REFUELING SHUT 00 CS LICENSE ABOVE COLD SiitJTDOW CATEGORY l'
1 SOL 1
2 OL
~
1 2
NON-LICENSED
'Does not include the licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel llandling, supervising refueling operations after the initial fuel loading.
s
- Shift crew composition nay be less than the minimum recuirements for a to exceed I hours in order to accommodate unexpected ab,sence of on duty shif t crew members provided immediate action is tak period of time not composition to within the minimum requirements of restore the shift crew Tab le 6.2-1, Additional Requirements:
At least one licensed Operator shall be in the control rocm 1.
when fuel is in the reactor.
r in the control At least two licensed Operators shall be present room during reactor start-up, scheduled reactor shutdown and 2.
during recovery from reactor trips.
An individual qualified in radiation protection procedures shall 3.
be on site when fuel is in the reactor.
All refueling operations after the initia! fuel loading shall be either a licensed Senior Reactor Operater 4.
directly supervised by or Senior Reactor Operator Limited to Fuel Handling who has ne other concurrent responsibilities during this operation.
j 5 individuals with fire protection training shall he
- 5'. At least These individuals shall not maintained onsite at all times.
include the minimum snift crew necessary for safe shutdown of the unit (2 members) or any personnel required for other essential functions during a fire emergency.
- This. change from 3 to 5 individuals will be implemented within 90 days of date of issuance of this license amendment.
d
-Us-Amandmert No. I6, J. 35 n