ML19326B720

From kanterella
Jump to navigation Jump to search
Forwards Addl Pages for Valve Wall Thickness Verification Program,Revision 3,requested in 740612 Telcon.Revision 3 Documents Corrective Action for Unresolved Valve Wall Thickness Item 72-12/2
Date released: 12/06/2019 Download: ML19326B720


Responds to AEC 720630 Ltr Re Valve Wall Thickness Verification.New Code Inapplicable.Valves Vital to Safety within Reactor Coolant Pressure Boundary Greater than 2 1/2 Ft Will Be Verified
ML19326B737
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 07/28/1972
From: Meek J
ARKANSAS POWER & LIGHT CO.
To: DAVIS J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19326B737 (2)
Forwards Valve Wall Thickness Verification Program & QA Audit Describing Corrective Action for Unresolved Item 72-12/2 in Response to AEC 720630 & 730702 Ltrs.Requests Review as Resolution of Item.W/O Encl
ML19326B732
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 12/07/1973
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: MOSELEY N C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19326B732 (3)
Forwards Pages 4,4a & Exhibit I as Addendum I to Valve Wall Thickness Verification Program Forwarded in Util 731207 Ltr. Provides Addl Info on Core Flood Valves CV-2415 & CV-2419
ML19326B729
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 02/01/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: MOSELEY N C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19326B729 (5)
Forwards Valve Wall Thickness Verification Program, Revision 3, & QA Audit Describing Corrective Action for Unresolved Item 72-12/2 in Response to AEC 720630 & 730216 Ltrs.W/O Encl
ML19326B727
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 05/31/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: MOSELEY N C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19326B727 (2)
Forwards Addl Pages for Valve Wall Thickness Verification Program,Revision 3,requested in 740612 Telcon.Revision 3 Documents Corrective Action for Unresolved Valve Wall Thickness Item 72-12/2
ML19326B719
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 06/25/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: MOSELEY N C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19326B719 (27)