ML19326B655

From kanterella
Jump to navigation Jump to search
Forwards AO 50-313/74-10A.JD Phillips Affidavit & AO 50-313/74-10 Encl
Date released: 12/06/2019 Download: ML19326B655


AO 50-313/74-10:on 741024,during Surveillance Test for Diesel Generators 1 & 2,both Generators Not Ready for Synchronization in Required 15-s.Cause Unknown.Subsequently Restarted Successfully.Investigation Continuing
ML19326B675
Person / Time
Site: Arkansas Nuclear 
Issue date: 10/24/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19326B675 (1)
AO 50-313/74-10:on 741025,leak from Cold Leg Loop Weld of RCS Was Discovered & Determined to Be Same Weld Reported in AO 50-313/74-09.Cause Unknown.Weld Removed & Sent to B&W Lab for Analysis
ML19326B665
Person / Time
Site: Arkansas Nuclear 
Issue date: 11/04/1974
From: Cavanaugh W, Kueter D, Phillips J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19326B665 (4)
Forwards AO 50-313/74-10.JD Phillips Affidavit Encl
ML19326B663
Person / Time
Site: Arkansas Nuclear 
Issue date: 11/04/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: CASE E G
US ATOMIC ENERGY COMMISSION (AEC)
References
Download: ML19326B663 (2)
AO 50-313/74-10A:on 741025,metallurgical Analysis Revealed That Leak from Cold Leg of RCS (AO 50-313/74-10) Caused by Failure of Weld Metal Due to Fatigue Fracture.Weld Rewelded & Expansion Loop Added
ML19326B659
Person / Time
Site: Arkansas Nuclear 
Issue date: 01/22/1975
From: Cavanaugh W, Phillips J, Rueter D
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19326B659 (15)
Forwards AO 50-313/74-10A.JD Phillips Affidavit & AO 50-313/74-10 Encl
ML19326B654
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/05/1975
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: CASE E G
Office of Nuclear Reactor Regulation
References
Download: ML19326B654 (2)