ML19326A763

From kanterella
Jump to navigation Jump to search
Forwards Deficiency Rept Re Cavitation Problems During Last Three Stages of Letdown Orifice in Rcs.Revision to Makeup Pump Recirculation Orifice Prone to Cavitation.Orifice to Be Returned to Manufacturer for Mod
ML19326A763
Person / Time
Site: Crystal River 
Issue date: 10/08/1974
From: Rodgers J
FLORIDA POWER CORP.
To: Knuth D
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19326A755 List:
References
NUDOCS 8003030893
Download: ML19326A763 (1)


Text

-

' Nq iO % (y*.

E,

.?

r )< l,.,.,_ Lf,c.. i;}'

Yun

\\

- iva Florida Power october 8, 1974 Co m po n a t oo m Donald F. Knuth, Director

'lhe Directorate of Regulatory Operations U. S. Atomic Energy Commission Washington, D. C.

20545

Subject:

50-302

Dear Mr. Knuth:

In accordance with Federal Regulation 10CFR50.55(e), we wish to report that we have been advised by Babcock 6 Wilcox Company of the results of an investigation they undertook regarding the letdown orifice installed-in the reactor coolant system. Reir investigation revealed that cavitation and subsequent erosion would occur in the last three stages of the letdown orifice. Additionally, their investigation indicated that the revision to the make-up, pump recirculation orifice also was subject to cavitation. He later' item is covered by a previous report. At the direction of BGW. we are returning the subject orifice v/

to the manufacturer for modification.

It is expected that this modifica-tion will assure that the problem will not occur at Crystal River Unit #3.

I am enclosing a summary report that delineates the identification of the problem, it s effect on the system, and the corrective action.

If you have any further questions, please advise us.

Very tnily yours,Og Idh J. T. Rodgers Assistant Vice President Attachment cc:

M. H. Kleinman N. C. Moseley, Director Region II, AEC/DRO O'

8008030 3

General Office 32o inirty-rourtn street soutn. P O Box 14042, st. Petersburg, Florida 33733 e 813-866-5151

...