Forwards ins Rept 44-2-288 Re Investigation of Irregularities in Fabrication of Steam Generators.W/O Encl. QA Insp Rept 999-42/72-01 Documentation Encl
ML19326A023
Person / Time
Site: Davis Besse, Oconee, Rancho Seco  
Issue date: 04/03/1972
From: Engelken R
US ATOMIC ENERGY COMMISSION (AEC)
To: Deyoung R, Maccary R
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19326A024 List:
References
REF-QA-99900042 NUDOCS 8001310598
Download: ML19326A023 (1)


Text

  • j O

UNITED STATES

  • I C':)*.' 1 5

ATOMIC ENERGY COMMISSION r~N g

\\

.*'y WASHINGTON. D.C. 20545 L {V

\\;-0J/

,,,,,, o APR 3 C2 R. C. DcYoung, Assistant Director for MTR's, DRL R. R. Haccary, Assistaat Director for Engineering DRS I VSSTICATION R2180RT ALLUGZD IRadGUIl.kITIES AT THE EALCOC;; & UILC04 CQ2A.?!

Forwarded for information is a report of an investigation of alleged irregularities at the Babcock & Uilcox Compa..y (35'..)

relative to the fabricacion of steam 1,caerators for the hancho-Sgo and Dayis-Jonno-facilities.

Tac allegations teere :.ude by a former Eds; employee. The investigation was carried out by representatives of the Division of Compli'ance and the Division of Inspection, in response to iaformation supplied by the office of Congressman Jack 'I.

I;emp.

As may be noted, the use of eight plates in an impro,,erly acac treaced condition in units for the cwo facilities uns confirmed

  • wy the investigation.

Ho other deficiencies were ideatified.

This matter was discussed with you previously, resulci..g i..

D letters from the Division of Reactor Licensing to the respective licensces. Uc would be pleased to assist in che evaluacion of s

the licensecs' responses; however, we pl.au no further action wich respect to shop inspection of the units in question.

If you have questions on this matter, please advise.

p r /% pru.

t u

px

~

vd. H. Jagelken, Assistant Director for Inspection and 2niorcemenc Division of Compliance Jaciosure:

IJS apt 44-2-283 dtd 3/14/72 cc:w/ encl.

4 ;ow y

orablich, Jr, CO CO
I, III & V

\\

jim O-1/L ?

SOO lN o 6 v

aay%

<