I

ofFicaq

s

. ..

OCT 311989

F

!

l

Docket Nos. 50-325, 50-324

License Nos. DPR-71 DPR-62

Carolina Power and Light Company

ATTN: Mr. Lynn W. Eury

Executive Vice President

Power Supply

P. O. Box 1551

!'

Raleigh, NC 27602

Gentlemen:

SUBJECT:

NOTICE OF VIOLATION

(NRC INSPECTION REPORT NOS. 50-325/89-31AND50-324/89-31)

This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by

A. Gooden on September 18-22, 1989.

The inspection included a review of

activities authorized for your Brunswick facility.

At the conclusion of the

inspection, the findings were discussed with those members of your staff

identified in the enclosed Inspection Report.

Areas examined during the inspection are identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

The inspection findings indicate that certain activities appeared to violate

NRC requirements.

The violations, references to pertinent requirements, and

'

elements to be included in your response are described in the enclosed Notice

of Violation.

The enclosed Inspection Report documents an oral commitment (see Paragraph 10)

made by a licensee representative and discussed in the exit interview.

If your

understanding of this commitment differs from the report statements, please

inform this office promptly.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2

Title 10 Coda of Federal Regulations, a copy of this letter and its enclosures

will be placed in the NRC Public Docuraent Room.

The responses directed by this letter and its enclosures are not subject to the

clearance procedures of the Office of Management and Budget as required by the

Paperwork Reduction Act of 1980, Pub. L. No.96-511.

!

~

8911130336 891031

I

l

PDR

ADDCK 05000324

Q

PNV

'

  • C'

'

-

---

y

7 7

_

_ _ _ _ _ __ .__ - - .

LF

,

" } .' J ?

l

.

[-

!

l

Carolina Power and Light Company

2

l

t

I

l

li .

Should you have any questions concerning this letter, please contact us.

i

F

i

Sincerely,

j

i

'

l

i-

!

x

E'

,

.

t

Douglas M. Collins, Chief

j

L.

Emergency Preparedness and

i

Radiological Protection Branch

j

h

Division of Radiation Safety

'

,

and Safeguards

.;

[:

'

"

'

Enclosures: ..

1.

Notice of Violation

2.

NRC Inspection Report

cc w/encls:

'

R. B. Starkey, Jr., Manager

Brunswick Nuclear Project

!

Box 10429

.

Southport, NC 28461

I

J. L. Harness

'

Plant General Manager

!

Brunswick Steam Electric Plant ~

!

P. O. Box 10429

Southport, NC 28461

!

R. E. Jones, General Counsel

i

Carolina Power & Light Company

~

-P. O. Box 1551

i

Raleigh, NC 27602

-l

Ms. Frankie Rabon

Board of Commissioners

'

P. O. Box 249

Bolivia, NC 28422

l

Chrys Bagget

'

State Clearinghouse

L

Budget and Management

116 West Jones Street

Raleigh, NC 27603

i.

l

(cc w/encls cont'd - see page 3)

1

l

,-

-

J

. . -

t

.i

Carol na Power and Light Company

3

(ccw/enclscont'd)

Dayne H. Brown, Chief

Radiation Protection Branch

Division of Facility Services

J,

N. C. Department of Human Resources

701 Barbour Drive

Raleigh, NC 27603-2008

H. A. Cole

Special Deputy Attorney General

State of North Carolina

P. O. Box 629

Raleigh, NC 27602

Robert P. Gruber

Executive Director

Public Staff - NCUC

P. O. Box 29520

Raleigh, NC 27626-0520

State of North Carolina

bec w/encls:

Document Control Desk

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

Star Rte.1. Box 208

Southport, NC 28461

R. A. Erickson, NRR/EPB

J. C. Heard, FEMA Region 'Y

,

.

RII: Q3SS

SS

RII:DRPd

Q cS.

(W

f8h

b

/f89

l

,

-