November 2, 1989 Wlalasi J. CAal. Jr.
rase r,a rmwm j
U. S. Nuclear Regulatory Commission Attn Document ~ Control Desk Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 60 445 AND 50-446 NRC BULLETIN 88-11:
PRESSURIZER SURGE LINE THERMAL STRATIFICATION AND LEAK BEFORE BREAK ADDITIONAL INFORMATION REF:
- 1) -TV Electric letter (TXX 89228) from W. J. Cahill, Jr.
to NRC dated May 1, 1989.
- 2) TV Electric letter (TXX 89706) from W. J. Cahill, Jr.
to NRC dated-September 15, 1989.
.3)
TV Electric letter (TXX-89765) from W. J. Cahill, Jr.
to NRC dated October 24, 1989.
Gen'tlement
.s.
On May 1, 1989, by reference (1). TU Electric submitted its response to NRC Bulletin 88-11.
Reference (1) transmitted a plant specific evaluation of the i
effects of thermal stratification on the Comanche Peak Unit 1 Pressurizer Surge Line (Surge Line) and its ability to satisfy leak-before break criteria.
l TV Electric subsequently provided, by reference (2), responses to NRC j
l questions and clarifying information on the plant specific evaluation.
1 l,
Reference (3) provided additional information regarding Surge Line leak-l-
before-break qualification.
In response to additional verbal requests from p
the NRC staff, this letter provides clarifying information on the plant specific evaluation in a total of two attachments and two enclosures.
The first attachment provides the required affidavit in accordance with the requirement of HRC Bulletin 88 11 that responses be submitted under oath or i
affirmation under the previsions of section 182a Atomic Energy Act of 1954, i,
l as amended.
The second attachment consists of a Westinghouse Application for l
i =
Withholding, CAW 89-107, Accompanying Affidavit, CAW-88 129, and Proprietary 1
Information Notice.
The first enclosure consists of five (5) copies of WCAP-12248 Supplement 2.
i entitled " Additional Information in Support of the Evaluation of Thermal 1
Stratification for the Comanche Peak Unit 1 Pressurizer Surge Line" (Proprietary).
YN
), a,,,
- L W I
IMf 8911000402 891102 i ' #8
/MC M8-f IMf PDR ADOCK 05000445 3 Man 8
ggf g IN(
.A PDC P, O. Box 100: Glen one, Texas 7 11002
.LY
r TXX 89792 November 2, 1989 Page 2 of The second enclosure consists of five (5) copies of WCAP-12247 Supplement 2, entitled " Additional Information in Support of the Evaluation of Thermal Stratification for the Comanche Peak Unit 1 Pressurizer Surge Line" (Non Proprietary).
As this submittal contains information proprietary to Westinghouse Electric Corporation, it'is supported by an affidavit signed by Westinghouse, the owner of the information.
The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of 10CFR2.790, i
Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR2.790.
Correspondence with respect to the proprietary aspects of the application for withholding should raference CAW 89 107 or should reference the supporting Westinghouse affidavit, CAW 88-129, and be addressed to R. A. Wieseman, Manager Regulatory and Legislative Aff airs Westinghouse Electric Corporation, P. O. Box 355, Pittsburgh, Pennsylvania 15230.
The calculated pipe support loads and displacements due to thermal stratification have been utilized in the final reconciliation of the stress reports for the CPSES Unit 1 Surge Line pipe supports.
If there are any questions, please contact H. A. Marvray at (214) 812-8296.
Sincerely, n
/
William J. Cahill, Jr.
i HAM /smp Attachments Enclosures (2) c - Mr. R. D. Martin, Region IV, w/o enclosures and attachments Resident Inspectors, CPSES (3), w/o enclosures and attachments
t
. Attachment I to TXX 89792 November UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
Texas Utilities Electric Company
)
Docket Nos 50 445
)
50 446 (Comanche Peak Steam Electric
)
Station, Units 1 & 2)
)
AFFIDAVIT William J. Cahill, Jr. being duly sworn, hereby deposes and says that he is Executive Vice President, Nuclear of TV Electric, the lead Applicant herein; that he is duly authorized to sign and file with the Nuclear Regulatory Commission this supplementary response to NRC Bulletin 88-11; that he is familiar with the content thereof; and that the matters set forth therein are true and correct to the best of his knowledge, information and belief.
/
William J. Ca Mil, Jr.
Executive Vice President, Nuclear l
l STATE OF TEXAS
)
)
COUNTY OF d w d )
Subscribed and sworn to before me, a Notary Public, on this / M day of M~) ew dC, 1989.
MQ[j PATRICIA WILSON Notary Publie WY COMNi!> SON EXP(f25 March 16,1993
._ -