Text

.

'

T)C h

.;

'

[

,.

...... .

,

>

.

.

.

00T 2 61989

,

'

Docket No. 50-461

Illinois Power Company

,

ATTN: Mr. D. P. Hall

Senior Vice President

Clinton Power Station

Mail Code V-275

'

P. O. Box 678

-

Clinton, Illinois 61727

l

Gentlemen:

.

This refers to the routine safety inspection conducted by Messrs. P. G. Brochman,

i

S. P. Ray, and B. S. Drouin of this office on August 18 through: 0ctober 6 1989,

,

of activities at Clinton Power Station authorized by NRC Operating License-

!

No. NPF-62, and to the discussion of our findings with Mr. .J. .S. Perry and others

-'

of your staff at the conclusion of the inspection.

'

The enclosed copy of our inspection report identifies areas' examined during: the

'

inspection. Within these areas, the inspection consisted of a selective

examination of procedures and representative records, observations, and

interviews with personnel.

During this inspection, certain of your activities appeared to'be in violatior

.i

of NRC requirements as described in the enclosed Notice and as discussed-in

Paragraph 3b(2). A written response is required. 'This issue was reviewed for

potential escalated enforcement action, however, based on limited safety

i

significance our review determined the violation to be more properly

,

categorized at a Severity Level IV. Although we did not chose.to utilize the

'

provisions of 10 CFR 2 Appendix C for exercise of discretion, we acknowledge

'

and encourage the self identification and reporting of this issue by

H

Illinois Power.

i

.

In accordance with 10 CFR 2.790 of .the Commission's regulations, a copy of

-

this letter and the enclosed inspection report will be placed in the NRC

j,

Public Document Room.

,

l

$0i

i

!

8911020233 891026

I t

i

PDR

ADOCK 05000461

r

Q

PDC

,

RII

RIII

R

RIII

RII e

i

MM

Y-

. kno ,

Gro06

GrBennan

4\\

b>b b

.

Drouin/pb

Rin

//L

\\%

to tW

to 2. O '

l

L

j

,

(^

.

-

,

-

.

.

.

.

-

-

.

.

c .,

..

-

.

'

.

[

OCT26

'

1939

Docket No. 50-461

-

f

Illinois Power Company

!

ATTN: Mr. D. P. Hall

l

Senior Vice President

Clinton Power Station

Mail Code V-275

P. O. Box 678

Clinton, Illinois 61727

Gentlemen:

l

This refers to the routine safety inspection conducted by Messrs. P. G. Brochman,

!

S. P. Ray, and B. S. Drouin of this office on August 18 through October 6, 1989,

of activities at Clinton Power Station authorized by NRC Operating License

No. NPF-62, and to the discussion of our findings with Mr. J. S. Perry and others

of your staff at the conclusion of the inspection.-

l

The enclosed copy of our inspection report identifies areas examined during the

!

inspection.

Within these areas, the inspection consisted of a selective

!

examination of procedures and representative records, observations, and

interviews with personnel.

l

During thir, inspection, certain of your activities a

of HRC requirements as discussed in Paragraph 3b(2) ppeared to be in violation

1

This issue is being

j

reviewed for potential escalated enforcement action.

You will be notified by

i

separate correspondence of our decision regarditic enforcement action for this

i

issue. We are releasing this report at this time for your information.

No

!

written response is required until you are notified of out actions.

!

i

,

L

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and t!.e enclosed inspection report will be placed in the NRC

j

I

Public Document Room.

We whi gladly discuss any questions you have concerning this inspection.

Sincerely,

j

i

'

l

Edward G. Greenman, Director

i

DivisionofReactorProjects

j

\\

l

Enclosure:

Inspection Report

I

No. 50-461/89027(DRP)

i

i

.See Attached Distribution

,g

RIII

RIII

RIII

RIII

!

n/,gd

+ % g ng * Knog,1

e

Greenman

i

$U

)

.-

e

I

<

J

.,.

. .. . . ' -

'

.

..,

Illinois Power Company

2

Distribution

cc w/ enclosure:

J. S. PerryIdent

Assistant

Vice Pres

D. L. Holtrscher, Acting Manager,

Licensing and Safety-

Department

D00/006 (RIDS)

Licensing feetManagement Branch

Resident Inspector, RI!!

J. B. Hickman, NRR Project Manager

J.W.McCaffreyIsionChief, Public

Utili+.ies Div

David Rosenblatt, Governor's

Office of Consumer Services

Sheldon Zabel.. Esquire

Sc'niff,Hardin,&Walte

Chairman of DeWitt County

Illinois Department of

Nuclear Safety

1

.

E

i

'

>

c 1 .

s

, ,.

-

p

+--

.