r Appendix A NOTICE OF VIOLATION Commonwealth Edison Company Docket No. 50-265 Based on the inspection conducted on March 9-11, 1980, it appears that one of your activities was in noncompliance with NRC requirements, as noted below. This item is a deficiency.

Technical Specification 6.2.A requires that " Detailed written procedures including applicable checkoff lists....shall be prepared, approved, and adhered to."

Contrary to the above, Procedure QTS 150-57, Revision 6, " Unit 2 IPCLRT Valve Lineup," was not adhered to in that valve position verfication was not carried out on March 8, 1980, to verify that Valves 2-1402-33A and 2-1402-33B (local leak test valves for core spray isolation valves) were locked closed as required.

8005270039 e

Q

- - -