05000368/LER-1980-020, Forwards LER 80-020/03L-0

From kanterella
(Redirected from ML19323C922)
Jump to navigation Jump to search
Forwards LER 80-020/03L-0
ML19323C922
Person / Time
Site: Arkansas Nuclear 
Issue date: 05/14/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19323C924 List:
References
2-050-12, 2-50-12, NUDOCS 8005190416
Download: ML19323C922 (1)


LER-1980-020, Forwards LER 80-020/03L-0
Event date:
Report date:
3681980020R00 - NRC Website

text

,

p.r -

S005190 4 / 6 ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 LITTLE ROCK, ARKANSAS 72203 (5011071-4000 May 14, 1980 2-050-12 Mr. K. V. Seyfrit, Director Office of Inspection & Enforcement U. S. fiucle r Regulatory Conmission Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Subject: Arkansas fluclear One - Unit 2 Docket tio. 50-368 License fio. flPF-6 Licensee Event Report tio. 80-020/03L-0 (File:

2-0520)

Gentlemen:

In accordance with Arkansas fluclear One Unit 2 Technical Specification 6.9.1.9.b, attached is the subject report concerning the pressurizer code safety valve (2PSV-4833) that was inoperable during Mode 3 opera-tion.

Very truly yours, u: 1

./

A > David C. Trimble 8

Manager, Licensing DCT:GAC:skn Attachment cc: Mr. Victor Stello, Jr., Director Office of Inspection & Enforcement U. S. fiuclear Regulatory Cox,ission Washington, D. C.

20555 Mr. florman M. Haller, Director Office of Management & Program Analysis U. S. fluclear Regulatory Commission Washington, D. C.

20555 l

MEMBEA MIDDLE SOUTH UTIUTIES SYSTEM