O TESTIMONY OF DR. MORTON I. GOLDMAN REVISED PARAGRAPH, PAGE 34 Applying a similar approach to the large mine PNL model [14],
I calculate that during the 17 year mine life, 8.76 (8.78) x 106 MT of sub-ore averaging 0. 015 % (0. 0155 % ) U 03 8 would have been accum-ulated with a total Ra-226 content of 367.6 (384.3) Ci, emitting 279 (300) Ci/yr of Rn-222.
In this model, the sub-ore pile is 100 feet in height and 1590 (1150) feet in base diameter; its com-plete erosion in any reasonable time frame seems highly unlikely.
Nevertheless, assuming this pile to be completely dispersed, the resulting Rn-222 emission would be about 4860 (5100) C1/yr, 4580 (4800) Ci/yr more than that caculated by PNL for the sub-ore pile, or an increase in the emission per AFR-year from 39 I,33) Ci to 3
169 (139) Ci Rn-222.
geoz2.60 % [
UNITED STATES OF AMERICA 3
NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOARD In the Matter of
)
)
METROPOLITAN EDISON COMPANY, ET AL
)
Docket Uc. 50-320
)
(Three Mile Island Nuclear Station,
)
Unit 2)
)
SERVICE LISI Alan S.
Rosenthal, Esquire Chairman U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Dr. W.
Reed Johnson, Member Atomic Safety and Licensing Appeal Board U.
S. Nuclear Rer:r '.atory Commission Washington, D.
C 20555 Mr. Gustave A. Linenberger Atemic Safety and Licensing Board U. S. Nuclear Regulatory Ccmmission Washington, D. C.
20555 Dr. Ernest O.
Salo Professor Fisheries Research Institate, WH-10 University of Washington Seattis, Washington 98195 Lawrence J. Chandler, Esq.
Office of the Executive Legal Director U. S. Nuclear Regulatory Commission
(
Washington, D. C.
20555 Dr. Chauncy R. Kepford 433 Orlando Avenue State College, Pennsylvania 16801 Karin W.
Carter, Esquire Assistant Attorney General Office of Enforcement Department of Environmental Resources 709 Health and Welfare Building Harrisburg, Pennsylvania 17120
Atomic Safety cud Licensing Appeal Board Panel U. S. Nuclear Regt:.latory Ccamission Washington, D.
C.
20555 Atomic Safety and Licensing Board Panel U.
S. Nuclear Regulatory Commission Washington, D.
C.
20555 l
l m
1
/
l l
UNITED STATES OF AMERICA NUCTJ.AR REGULATORY COMMISSION B_EFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOARD IF, the Matter of
)
)
PUBLIC SERVICE ELECTRIC
)
Docket Nos. 50-354
)
50-355
)
(Hope Creek Generating Station,
)
Units 1 and 2)
)
SERVICE LIST Richard S. Salzman, Esquire Atomic Safety and Licensing Appeal Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Dr. W. Reed Johnson Atomic Safety and Licensing Appeal Board Panel U.
S. Nuclear Regulatory Commission Washington, D.
C.
20555 Dr. Oscar H. Paris Atemic Safety and Licensing Board Panel U.
S. Nuclear Regulatory Ccemission Washington, D.
C.
20555 Mr. Ernest E.
Hill Lawrence Livermore Laboratory University of California Post Office Box 808, L-123 Livermore, California 94550 Chairman, Atomic Safety and Licensing Board Panel U. S. Nuclear Regulatory Ccmmission Washington, D.
C.
20555 Chairman, Atomic Safety and Licensing Appeal Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.
20555
~
,,,.n.~
Honorable F. Michael Parkowski Mr. Chase R.
Stephens Deputy Attorney General Docketing and Service Section Department of Natural Resources Office of the Secretary and Environmental Control U.
S. Nuclear Regulatory Cc= mission Catnall Building Washington, D. C.
20555 Dover, Delaware 19901 Richard L. Black, Esquire Counsel for NRC Regulatory Staff Office of the Executive Legal Director U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Richard Fryling, Jr., Esquire Assistant General Solicitor Public Service Electric and Gas Ccmpany 80 Park Place, Rocm 7113 Newark, New Jersey 07101 Mark L. First, Esquire Deputy Attorney General State of New Jersey 36 West State Street
(
Trenton, New Jersey 08625 Mr. David A. Caccia R. D.
42 Box 70-A Sewell, New Jersey 08080 Peter Buchsbaum, Esquire Robert Westreich, Esquire Department of the Public Advocate Division of Public Interest Advocacy 520 East State Street Trenton, New Jersey 08625 William Horner, Esquire 67 Market Street Salem, New Jersey 08079 Dr. Paul Mecray, Jr.
Suite 303 Ccoper River Parkway West North Park Drive Pennsauken, New Jersey 08109 Dr. John R. Lamarsh 68 North Chatsworth Avenue
~~
La.chmont, New York 10538
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION 3EFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOARD In the Matter of
)
)
PHILADELPHIA ELECTRIC
)
Decket Nos. 50-277 COMPANY, ET AL
)
50-278
)
(Peach Bottom Atomic Power
)
Station, Units 2 and 3)
)
SERVICE LIST Michael C. Farrar, Esquire Chairman Atomic Safety and Licensing Appeal Board U.
S. Nuclear Regulatory Commission Washington, D. C.
20555 Dr. John H. Buck Member, Atemic Safety and Licensing Appeal Board U.
S. Nuclear Regulatory Ccmmission
(
Washington, D. C.
20555 Dr. W. Reed Johnson Atomic Safety and Licensing Appeal Board Panel U.
S. Nuclear Regulatory Commission Washington, D. C.
20555 Marshall E. Miller, Esquire Chairman Atomic Safety and Licensing Board Panel U.
S.
Nuclear Regulatory Ccmmission Washington, D. C<
20555 l
Dr. Kenneth A. McCollum College of Engineering Oklahoma State University l
Stillwater, Oklahoma 74072 Ernest O.
Salo Professor, Fisheries Research Institute, WH-10 University of Washington Seattle, Washington 98198
.d
Chairman, Atomic Safety and Licensing Appeal Board Panel U.
S. Nuclear Regulatory Ccmmission Washington, D. C.
20555 Karin Carter, Esquire Department of Environmental Resources Ccmmonwealth of Pennsylvania 505 Executive House Harrisburg, Pennsylvania 17120 John B, Griffith, Esquire Special Assistant Attorney General State of Maryland Department of Natural Resources Tawes State Office Building Annapolis, Maryland 21401 Myron Biccm, Esquire U.
S. Environmental Protection Agency Region III, Curtis Building 6th and Walnut Streets Philadelphia, Pennsylvania 19106 James M. Cut: chin, Esquire 1
Counsel for NRC Regulatory Staff Office of the Executive Legal Director U. S. Nuciaar Regulatory Commission Washingt on, D. C.
20555 Eugene J.
Bradley, Esquire Philadelphia Electric Ccmpany 2301 Market Street Philadelphia, Pennsylvania 19101 Mr. Chase R. Stephens Docketing and Service Section Office of the Secretary U.
S. Nuc19.ar Regulatory Ccmmission Washington, D. C.
20555 Raymond L. Hovis, Esquire Stock & Leader 35 South Ouke Street Ycrk, Pennsylvania 17401 Mr. Chauncey Kepford i
433 Orlando Avenue State College, Pennsylvania 16801 l'.
l l
i l
L
c UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOAPS In the Matter of
)
)
ROCHESTER GAS AND ELECTRIC
)
Docket No. STN 50-485 CORPORATION, et a1
)
)
(Sterling Power Project
)
Nuclear Unit No. 1)
)
SERVICE LIST Alan S. Rosenthal, Esquire Jeffrey L. Cohen, Esquire Chairman New York State Energy Office Atomic Safety and Licensing Swan Street Building Appeal Scard Core 1, Second Floor U. S. Nuclear Regulatory Commission Empire State Plaza Washingren, D. C.
20555 Albany, New York 12223 Dr. John H. Buck Mr. Lester Ko rnblith, Jr.
Atemic Safety and Licensing Atomic Safety and Licensing Appeal Scard Board U.
S. Nuclear Regulatory U.
S. Nuclear Regulatory Commission Washington, D. C.
20555 Commission Washington, D.
c.
20555 Richard S.
Salzman, Esquire Atomic Safety and Licensing Appeal Board U.
S. Nuclear Regulatory Commission Washington, D. C.
20555 Ms. Sharon Morey Ecology Action P. O. Box 94 Oswego, New York 13126 Dr. George C. Anderson Oceanography Department, WB-10 University of Washington Seattle, Washington 98195 l
l Stephen M.
Schinki, Esquire Office of the Executive Legal
~
Director U.
S. Nuclear Regulatory Commission i!y Washington, D.
C.
20555 l