Responds to NRC Re Violations Noted in IE Insp Repts 50-269/76-09,50-270/76-09 & 50-287/76-09.Corrective Actions:Training Conducted Re Issue & Storage of Precision Measuring Equipment.Repts Contain No Proprietary Info
ML19322B760
Person / Time
Site: Oconee  
Issue date: 09/02/1976
From: Parker W
DUKE POWER CO.
To: Moseley N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19322B749 List:
References
NUDOCS 7912050756
Download: ML19322B760 (2)


Text

_ _ _.

__m__._.

__..-m..

Dtrxn POWER COMPANY i

Powen Duri.orwo

/

422 SocTn Cuuncu STREET, CliARI.oTTE, N. C. 20242 wl L LI A M O. PA R R E R, J R.

VrCE Petsectmi Tettewom t:Asta 704 Strame PeOOwCTION 373-4063 September 2, 1976 J

Mr. Norman C. Moseley, Director U. S. Nuclear' Regulatory Commission Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 Re:

IE:II:TNE 50-269/76-7 50-270/76-7 50-287/76-7

Dear Mr. Moseley:

With regard to your letter of August 12, 1976, Duke Power Company does not consider information contained in IE Inspection Report 50-269,

-270, ~287/76-7 to be proprietary.

Please find attached our response to Item I.

Very truly yours, 3

/

William O. Parker, Jr.

LJB:vr Attachment 7912050 7 N O

,y 5-

RESPONSE TO IE INSPECTION REPORT 50-269, -270, -287/76-6 I

Contrary.to the requirements of Criterion XII of Appendix B to 10CFR50 as implemented by Section 17.2.12 of the Duke Power Company Topical Report on Quality Assurance Program, DUKE-1, certain safety-related test and measuring instruments, specifically strain gages and diaI indicators, were observed to be improperly tagged and stored with non-safety-related instruments on July 13, 1976.

RESPONSE

Specific training regarding the issue and storage of precision measuring and test equipment has been conducted to assure that all personnel understand and abide by the controls established for such equipment.

In addition, a separate tool and test equipment area for the Mechanical Maintenance Section is being established.

Two Storekeeper personnel have been assigned to control this area, and a system which will segregate safety-related equipment and facilitate the handling, storage and issuance of all tools and test equipment is being implemented.

The area will be fully operational by January 1,1977.

It is considered that the above j

action will provide adequate control and segregation of safety-related tools i

and test equipment.

)

i I

f

~ - - -..