ML19322B692

From kanterella
Jump to navigation Jump to search
Ro:On 770419,review of Composite Surface Water Samples Collected Jan-March 1977 Showed Excessive Level of Radioactivity.Anomalous Tritium Concentrations Present No Safety Hazard
ML19322B692
Person / Time
Site: Oconee  
Issue date: 04/26/1977
From: Parker W
DUKE POWER CO.
To:
References
NUDOCS 7912050696
Download: ML19322B692 (2)


Text

A i

\\

DUKE POWER COMPANY Powra Dun. nmo

(

422 Socin Cnuncu Srazer. CnAntorTz. N. C. asa42

[7 W I L LI A M O. PA R M E R, J R.

SCE Pm(S40t=T Tritowont:Anta 734 Seca= Paoowcwom 373-4083 April 26, 1977 Mr. Noruan C. Moseley, Director U. S. Nuclear Regulatory Commission Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 i

Re: Oconee Nuclear Station Docket Nos. 50-269, -270, -287

Dear Mr. Moseley:

Pursuant to the requirements of Oconee Nuclear Station Technical Specifi-cation 6.6.2.2.C. and D, this report is submitted describing conditions in wnich measured levels of radioactivity exceed the control levels by greater than four times but less than ten times and a condition in which measured levels of radioactivity exceeded the control level by greater than ten times.

On April 19, 1977, analytical results of composite surface water samples collected early in January, February, and March, 1977 were reviewed.

Given below is a summary of the pertinent results of the radioactivity concentrations of these samples:

Sample Location Type Sanple Tritium Concentration 000.S. Hwy. 183 Bridge N.

Surface (2.7 1 0.7)E-7 uC1/ml of site (Control) 000.7, Hwy. 183 Bridge S.

Surface (2.3 1 0.1)E-5 uCi/ml of site 005.2, Hwy. 27 Bridge at Surface (6.7 1 0.4)E-6 pCi/ml Newry 013 Hartwell Reservoir Surface (1.1 1 0.1)E-6 pCi/ml 5.8 mi. S. of Keowee Dam Tritium concentrations in the water samples collected are dependent upon the tritium concentrations of liquid effluent released from the station

?f 791205U67[

b'

t vig 1

Mr. Norman C. Moseley Page 2 April 26, 1977 prior to sampling. For the months of December,1976, January and February, 1977, a total of 504 curies of tritium were released from the station in liquid effluents.

The average tailrace coacentration of tritium was 1.3E-5 pCi/ml. This concentration compares favorably with the observed value at Location 000.7 near the effluent discharge point.

Dilution and dispersion of tritium in liquid effluents between Oconee Nuclear Station and the Clemson water intake has been calculated using the equation for instantaneous release taken from the U. S. Geological Survey. Paper No. 443-B, " Dispersion of Dissolved or Suspended Materials in Flowing Streams," by Robert E. Glover (1964), p.5.

This equation accounts for longitudinal dispersion only. Conservatism was used in selecting parameters for substitution in the instantaneous release equation to determine the concentration of effluents at the Clemson water intake.

These assumptions were (1) the elevation of Lake Hartwell is 654.00 feet, (2) the flow of the Keowee River is 1100 cfs, the yearly average and, (3) an average of two waste releases per day.

Using this method, the average concentration of tritium at the Clemson water intake should be approximately 1.4E-6 pCi/ml. This calculated tritium concentration is approximately the same as that observed in Hartwell Reservoir just up-stream of the Clemson water intake.

The Final Environmental Statement for Oconee states that "the largest estimates of dose to the individ" la from liquid effluents are at Clemson and Pendleton where drinking vater is withdrawn from the Keowee River.

The radionuclide making the most important contribution to dose at these

-ocations is tritium (more than 50 percent)." The dose estimate for any individual consuming Clemson water containing 1.4 E-6 pCi/ml of tritium is 0.14 mrem / year if these tritium concentrations were maintained over the year. This estimate of dose is less than 0.1% of the dose from natural background and less than 0.05% of the limits of 10CFR20. Therefore, it is concluded that the observed anomalous tritium concentrations do not adversely affect public health and safety.

Ve truly yours Ju oad

  • William O. Parker, Jr LJB:vr i