1 1

,,.. e. :...... y o i I n.y SEISMIC lCNITORING INSTRUMENTATION

[.!"!TI."G CONDITICN.00R OPEPATION 2..

.he seismic moni Oring instrumentation shcwn in. ble 3.3.6.2-1 s

sa a.s.o.4 shall be OPERA 3LE.

i AF:LICA3ILITY: At all times.

ACTICN:

With one er mere seismic monitoring instru ents inc:erable for a.

m:re than 30 days, in lieu of any other re:or recuired by Specification 5.9.1, prepare and submit a Special Report to the Commission cursuant to Specification 5.9.2 within the next l

10 days outlining the cause of the malfunc: ion and the plans for restering the instrument (s) to CPEPA5LE status.

I c.

The provisiens of Specifications 3.0.3 and 3.0.3 are not l

applicable.

(-

e le ur r i i.:JqC : rD 15:.v.

..l l 3 Me...

t w

...v

,i t

.4.o.:.1 taca or the above recuired seismic monitoring instruments

!ssall be demonstrated CPERABLE by the :erformance of the CHANNEL CHECK,

! FANNEL FUNCTIONAL TEST and CHANNEL CALIBRATICN operatic.ns at the lfre
uenciesshowninTable4.3.5.2-1.

r il.3.5.2.2 Cacn of the above recuired seismic moni cring ir.struments yac.ated during a saismic event shall be rest: red :c OPERABLE s stus

..itnin 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and a CHANNEL CALIBRATION performed within 5 days followirg the seismic event.

Data shall be retrieved frcm actuated instruments and analy:ed t0 determine :ne magnitude of the vibra:Ory

.;r:uno Otien.

In lieu cf any other report recuirec by Specifica:icn o5.9.i, a Special Re:or shall be pre:ared and submittsd : the C:m-

.a.

(. :..e.e 4...:.

i

._. =_.c.. :. ; r..

.r u.

lH

~

( I : _a ;9itude, frequency spectrum and resultant effect u;:n fa:ility features

. -.. a r.

. '.e 2 '. =..y.

i
I i,.

,,l t.

.. :-2.5 a /,,

--o

.-;r :.:,. :s o 80 07180 }12h

s TAELE 3.3.6.2-1 SEISMIC !CNITORIfiG INSTRU:'.ENTpTION MIlilMUM l'EASUREME:li IfiSTRUMENTS INSTRUMENTS AtiD SENSOR LOCATIONS p*NGE

_ OPERABLE 1.

Triaxial Time-History Accelerographs 1

a.

I b.

I

.c.

I d.

2.

Triaxial Peak Accelerographs f

a.

I D.

1 C.

]

d.

3.

Triaxial Seismic Skitches 1*

a.

1*

-b.

17 c.

4 Triaxial Response-Spectrum Recorders 1*

a.

I b.

With reactor control rocm indication and annunciation.

T

?

GE-STS 3/a 3..;7 A:ril 1, 1975 A

TABLE 4.3.6.2-l' SEISMIC MONITORING INSTRUMENTATION SURVEILLA' ICE ECUIREVENTS

.i CHANNEL CHANNEL FUNCTIONAL CHANNEL I' STRUM.E!iTS AND SENSOR LOCATIONS CHECK TEST CALI5 RATION 1.

Triaxial Time-History Accelerographs a.

M SA R

b.

M SA R

~

c.

M

.SA R

d.

M SA R

2.

Triaxial Peak Accelerographs a.

NA NA R

b.

NA NA R

c.

NA NA R

c.

NA NA R

3.

Triaxial Seismic Switche's a.

M*

SA R

b.

M SA R

c.

M SA R

(

~-

Triaxial Response-Spectrum Recorders a.

M SA R

b.

NA SA R

4 9

E.:s:: seismic rigger.

i 1E-ITS 3/4 2 43 A:ril 1, 1975 1