Forwards IE Info Notice 80-27, Degradation of Reactor Coolant Pump Studs. No Specific Action or Response Required
ML19320C153
Person / Time
Site: Wolf Creek 
Issue date: 06/11/1980
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Koester G
KANSAS GAS & ELECTRIC CO.
References
NUDOCS 8007160324
Download: ML19320C153 (1)


Text

____ _

PDR LPDR UNITED STATES TIC /

p *S C8%,[o,,

t

' NUCLEAR REGULATORY COMMISSION NSIC c

U REGloN IV CENTRAL FILES E

o 611 RY AN PLAZA DRIVE, SUITE 1000 f

ARLINGTON, TEXAS 76012 E '.,,

t EW..,,,n$

June 11, 1980 In Leply Refer To:

RIV Docket No.

STN 50-482/IE Information Notice No. 80-27 Kansas Gas & Electric Co.

Attn:

Mr. Glenn L. Koester Vice President-Operations Post Office Box 208 Wichita, Kansas 67201 Gentlemen:

This IE Information Notice is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the infor-mation for possible applicability to their facilities. No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, 1

l Karl V. Seyfrit Director

Enclosures:

1.

IE Information Notice No. 80-27 2.

List of Recently Issued IE Information Notices cc: w/ enclosures Messrs. Nicholas A. Petrick, SNUPPS D. T. McPhee, Kansas City Power and Light Company Gerald Charnoff, Shaw, Pittman, Potts & Trowbridge E. W. Creel, Kansas Gas and Electric Company 8007160328

~

..-Q

SSINS No.:

6835 Accession No.:

UNITED STATES 8005050068 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT T 4*g

" N(t,cm WASHINGTON, D.C.

20555 d

g IE Information Notice No. 80-27 Date: June 11, 1980 Page 1 of 2 DEGRADATION OF REACTOR COOLANT PUMP STUDS Description of Circumstances:

On May 17, 1980, th'e NRC staff was informed by Omaha Public Power District (OPPD) that severe corrosion damage was found on a number cf closure studs in two of the four Byron Jackson reactor coolant pumps at Fort Calhoun Unit 1 (PWR).

I At the time, the reactor coolant system was undergoing a routine low pressure i

leak test.(180 psig) and visual inspection prior to plant restart after a four-month outage for refueling, pipe support modifications and scheduled inservice i

inspection. During the visual inspection, saturated and dripping insulation was observed at one of the Byron Jackson reactor coolant pump flange regions.

Upon removal of the insulation, evidence of coolant 1.eakage was found emanating from the seating surfaces between the pump casing and the pump cover. Further investigation of the three remaining pumps indicated similar coolant leakage past both inner and outer flange gaskets on two of the three pumps. After complete removal of the nonmetallic insulation, further visual observations revealed three studs located side.-by-side on one pump and three studs similarly located on the other pump had significant corrosion wastage in the shank area next to the lower thread section in the pump casing flange. Wastage of approximately 50% of the original diameter of the stud giving them an " hour glass" type appearance was obse rved. The corroded studs were located in the vicinity of a component cooling water line on both affected pt;ps but no direct correlation of this fact has been established. Although not confirmed by metallurgical analysis, the cause of.the

. stud wastage is thought to be corrosive attack by hot boric acid from the primary coolant.

The pump cover and casing for these pumps are constructed of ASTM A-351, Grade CF8M stainless steel. -Sealing between the cover and casing is achieved by two l

concentric;304 stainless steel flexitallic gaskets. A leak-off line' installed between the gaskets on each pump was plugged and not instrumented. The leak-off I

line was not.in use and therefore, no indication of RCS leakage from the inner meal was available. Each pump has 16 closure studs, consisting of ASTM A-193 Grade'B7 low alloy steel, wnich are chrome plated in the thread area and l

phosphate coated in the shank area.

The studs are approximately 3-1/2 inches

-in diameter and about 29 inches long.

~

No maintenance requiring removal of the pump casing studs had been performed on the reactor coolant pumps since initial construction. The studs were covered l

IE Information Notice No. 80-27 Date: June 11, 1980 Page 2 of 2 with block type insulation since construction thereby limiting them from view.

The studs on two pumps were ultrasonically inspected in place in accordance with the applicable ASME Section XI code rules.

These ultrasonic examinations were intended to locate cracks in bolting and were not effective in revealing wastage of the studs.

The three affected pumps will be disassembled for further cleaning and inspection of the studs and mating surfaces.

Prior to reassembly, all studs exhibiting significant corrosion will be replaced. All new, or acceptable used studs, will be subjected to ultrasonic, visual and magnetic particle examinations.

-Installation of instrumentation for actively monitoring the leak-off lines between the flexitallic gaskets is being performed. Future inservice inspec-tions, presently limited to ultrasonic examinstion, will be supplemented with visual examination of the studs installed in the reactor coolant pumps.

Replace-ment insulation will be in the form of a removable blanket to facilitate visual examination.

The condition of the studs discovered at Ft. Calhoun raises concerns that such severe corrosion, if undetected, could lead to stud failures which could result in loss of integrity of the reactor coolant pressure boundary.

The lack of

- effectiveness of current ultrasonic examinations in revealing wastage emphasizes the need for supplemental visual inspections and use of instrumented leak detec-tion systems to preclude unacceptable stud degradation going undetected.

Licensees

-should' consider that the potential for undetected wastage of carbon steel bolting by a similar mechanism could exist in other components such as valves.

This IE Information Notice is provided as an early notification of a signi-ficant matter that is still under review by the NRC staff.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or written response to this IE Information Notice is required.

If NRC evaluations so indicate, further licensee actions may be required.

i l

,__m.

IE Information Notice No. 80-27 June 11, 1980 LISTING OF RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued To Notice No.

Issued 80-21 Anchorage and Support of 5/16/80 All power reactor Safety-Related Electrical facilities with an Equipment eQperating License (OL) or Construction Permit (CP) 80-22 Breakdown In Contamination 5/28/80 All pcwer reactor Control Programs Operating Licenses (OLs) and near term Construction Permits (cps) 23 Loss of Suction 5/29/80 All power reactor to Emergency Feedwater facilities with an Pumps Operating License (OL) or Construction Permit (CP) 80-24 Low Level Radioactive 5/30/80 All NRC and Agreement i