05000346/LER-1980-048-01, /01T-0:on 800627,during IE Bulletin 79-14 Insp, Pipe Support HCB-40-B1 Found Not Installed & CCA-8-H15 Found Mislocated.Caused by Initial Const/Installation Error. Supports Will Be Installed in Proper Locations

From kanterella
(Redirected from ML19320B966)
Jump to navigation Jump to search
/01T-0:on 800627,during IE Bulletin 79-14 Insp, Pipe Support HCB-40-B1 Found Not Installed & CCA-8-H15 Found Mislocated.Caused by Initial Const/Installation Error. Supports Will Be Installed in Proper Locations
ML19320B966
Person / Time
Site: Davis Besse 
Issue date: 07/10/1980
From: Mekbel C
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19320B963 List:
References
IEB-79-14, LER-80-048-01T, LER-80-48-1T, NUDOCS 8007150566
Download: ML19320B966 (2)


LER-1980-048, /01T-0:on 800627,during IE Bulletin 79-14 Insp, Pipe Support HCB-40-B1 Found Not Installed & CCA-8-H15 Found Mislocated.Caused by Initial Const/Installation Error. Supports Will Be Installed in Proper Locations
Event date:
Report date:
3461980048R01 - NRC Website

text

NRC F E RJ 3GG -

U. S. NUCLEAR REGULATORY COMMISSION (7 71)

LICENSEE EVENT REPORT 4

CONTROL BLOCK: l l

l l

l l

Ih (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) i e

l0 l1l l OlH l Dl Bl Sl 1l@l 0l 0l 0l 0l 0l 0l 0l 0 l 0 l dl d l@l 4 l 1l ll 1l 1l@l l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBEM 25 26 LICENSE TYPE J0 57 CAT $8 CON'T ll 0 I 1 I l l-l@l 0l 5 l 0l -l 0 l 3 l 4 l 6 @l 0 l 6 l 2 l 7 l 8 l 0 j@l0 l 7 l 1l,01 8 l 0 l@

OuRC 7

8 60 61 DOCK ET NUVB ER 68 69 EVENT OATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lol2l l (NP-32-80-09) While evaluating the inaccessible pipdng systems as required by IE Bullet-lo la l l tin 79-14, pipe support HCB-40-B1 was found not installed and CCA-8-H15 was found mis-j l o 14 l l located.

It was determined that the found condition was less conservative than l

Jo}sl l assumed in the accident analysis of the safety analysy report and is being reported l lo is l l under Technical Specification 6.9.1.8.1.

There was no danger to the health and l

lo l 7 l l safety of the public or station personnel.

I lois i l l

80 7

8 9 E

CODE SUCC E COMPONENT CODE SUBC DE S

E l0 l9l l Xl Xl@ l Bl@ l C l@ l5 lU lP l0 lR lT l@ l Bl@ ]@

y 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LE R EVENT YE AR RENRT NO.

CODE TYPE No.

O a y, g/ROl810l l-l 1014l8l l/l l0 l1 l [TJ l_l l 0l s

,21 22 23 24 26 27 28 29 30 31 32 E

A O

ON PL NT MET HOURS 72 S38$si E FOR b 8.

SUP Ll MANUFA TURER l F lgl34Z lg lZ lg gg l0j0l0l l

]g l Nlg [Zjg l Z l 9 l 9 l9 lg 33 3b 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h [TTin i The cause of the occurrence was an initial construction / installation error. HCB-40-B1j l was never installed and CCA-8-H15 was mislocated. Under FCR 80-091 Supplement 6, i i

,,,7i l HCB-40-B1 will be added and CCA-8-H15 will be redesigned and relocated to its original l g l position under'FCR 80-131 Supplement 3.

l t 4 l

l T-S 9 80 S

% POWER OTHER STATUS IS O RY DISCOVERY DESCRIPTION

[ TIT l ]@ l 0 l 0 l 0 l@l NA l

Jgl IE Bulletin 79-14 l

A TivlTY CO TENT r,ELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE l1 l6 l [Zj @ [Zjgl NA l

l NA l'

PERSONNEL EXPOS ES DESCRiPrioN @

NuMBEn TYPE y l0l0l0l@ ] @l NA l

2 u

80 PenSONNE t iN;u'iliES NUMBER

DESCRIPTION

10l0l01@l NA l

i 4 9

8 9 11 12 80 LOSS OF oR DAMAGE TO FACILITY TYPE

DESCRIPTION

LzJ@l NA l

1 9 7

8 9 10 80 ISSU

DESCRIPTION

E L.SESI l

lllllllllllll$

NA

$UU71505he c8 59 so s 8 9 10 Charles Mekbel 419-259-5608 2

WR 80-103 NAME OF PREPJ!RER PHONE:

L

e TOLEDO EDISON COMFANY DAVIS-BESSE NUCLEAR POWER STATION UNIT ONE SUPPLEMENTAL INFORMATION FOR LER NP-32-80-09 DATE OF EVENT: June 27, 1980 FACILITY: Davis-Besse Unit 1 IDENTIFICATION OF OCCURRENCE: Pipe supports HCB-40-B1 and CCA-8-H15 not installed Es designed i

I Conditions Prior to Occurrence: The unit was in Mode 6, with Power (MWT) = 0 and k'

1Lsad (Gross MWE) = 0.

Discription of Occurrence: While performin3 the walkdown and engineering evaluation for inaccessible piping systems required by IE Bulletin 79-14, the following was found:

Pipe support HCB-40-B1 on the component cooling water (CCW) supply to the control rod drive (CRD) mechanism coolers was not installed. This would have left approxi-mately 21 feet of 3 inch pipe between the containment penetration and the isolation valve laterally unrestrained during an earthquake.

Lateral restraint CCA-8-H15 on the pressurizer relief inlet was located about 9 inches

'from its analyzed location..This descrepancy would have caused an overstressed con-dition in a welded attachment to this line during an earthquake.

I During the detailed engineering evaluation of these descrepancies, it was determined

.that the'found condition was less conservative than assumed in the accident analysis j

of the safety analysis report and is being reported under Technical Specification i

6.9.1.8.1.

l-n Designation of Apparent Cause of Occurrence: The cause of the occurrence was an ini-tial construction / installation error. HCB-40-B1 was never installed and CCA-8-H15 l

1 w2s mislocated.

' Analysis of Occurrence: There was no danger to th'c health and safety of the public or to station personnel. These restraints do not affect normal unit operation.. Pipe support HCB-40-H1 is only required to resist loads resulting from-a design basis c:rthquake. Lateral. restraint CCA-8-H15, in its as-found condition, would not have bten overstressed except during a' design b. sis earthquake, since 98% of the restraints drsign load is scismic.-

Cirrective Action: _ Pipe support HCB-40-B1 will be added under FCR 80-091 Supplement 6.

Lateral restraint CCA-8-H15.will.be redesigned and relocated to its original Position under FCR 80-131 Supplement 3.

These descrepancies will be'ecrrected prior to startup from the current refueling outage.

Failure' Data: There have been no previous reported findings where the installation was not per design.

' LER' #80-048 '

1