Forwards Status Rept Re Burnable Poison Rod Separation from Fuel Assembly & Subsequent Recovery.Also Forwards Schedule of Repts Re Final Investigative Results & Analyses to Justify Continued Operation.Further Submittal Due 780515
ML19319D379
Person / Time
Site: Crystal River 
Issue date: 05/04/1978
From: Stewart W
FLORIDA POWER CORP.
To: Nelson C
Office of Nuclear Reactor Regulation
Shared Package
ML19319D380 List:
References
FOIA-79-149 NUDOCS 8003160213
Download: ML19319D379 (3)


Text

'

]

i O

/

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

DISTRIBUTION FOR INCOMINO MATERIAL 50-302 REC: NELSON C C ORO: STEWART U P DOCDATE: 05/04/79 NRC FL PWR DATE RCVD: 05/09/79 DOCTYPC: LETTER NOTARIZED: YES COPIES RECEIVED

SUBJECT:

LTR ?

ENCL 40 FORWARDING STATUS REPT SUMMARIZING EVENTS AT UNIT S RELATED TO DURNABLE POISON ROD SEPARATION FROM RESPECTIVE FUEL ASSEMBLY & SUBSEQUENT RECOVERY FROM THAT-EVENT.

W/ATT SCHEDULE OF REPT CUBMITTALS DOCUMENTING FINAL INVESTIGATIVE RESULTS & ANALYSES FOR CoMapuao oestAnsu PLANT NAME: CRYSTAL RIVER 413 REVIEWER INITIAL:

XJM DISTRIBUTOR INITIAL:

                                  • DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS *************++++*

GENERAL DISTRIBUTION FOR AFTER. ISSUANCE OF OPERATING LICENSE.

(DISTRIBUTION CODE A001)

FOR ACTION.

DR CHIEF REID**W/7 ENCL INTERNAL:

REG FILE **W/ ENCL NRC PDR**W/ ENCL I & E**W/2 ENCL OELD**LTR ONLY HANAUER**W/ ENCL CHECK **W/ ENCL EISENHUT**W/ ENCL SHAO**W/ ENCL DAER**W/ ENCL BUTLER **W/ ENCL EEE**W/ ENCL J COLLINS **W/ ENCL J.

MCGOUGH+-*W/ ENCL EXTERNAL:

LPDR'S CRYSTAL RIVER, FL**W/ ENCL TIC **W/ ENCL NSIC+*W/ ENCL ACRS CAT De*W/16 ENCL l

l D

QS

'@d h

.L 7o CONTROL NER.

TnE eND

  • m m.4. m * *..... -.. <. -. ;

80031 sop g P

l

&?'?A%

~

h[j SIEGHIORY E%E.T E.E COPY c

f.

ODO M

Power

  • ff."Aahaafs8" CORPOAaT*0N May 4, 1978 Mr. C. C. Nelson, Prcject_ Manager i

fl Operating Reactors Branch No. 4

'i

i Office of NRR 3.I U. S. Nuclear Regulatory Commission

(~]

Washington, D.C.

20555 2:1 E.5

Reference:

Crystal River Unit No. 3

'3 Docket No. 50-302 E

Operating Licensing No. DPR-72 Floridt Power Corporation

Dear Mr. Nelson:

Enclosed for your information is a status report summarizing the events at the Florida Power Corporation, Crystal River Unit 3 Plant as related to the burnable poison rod separation from its respective fuel assembly and subsequent recovery from that event. Also includeo is a schedule of report submittals to the NRC documenting the final investigative results and analyses to justify continued operation of Crystal River Unit 3.

This report is not intended to respond to questions transmitted in your letter of May 2,1978. - Detailea responses to Part 1 of your request for information will be submitted May 15, 1978.

Our final submittals, given in the attached summary, will address questions given in Part 11 of your May 2 letter.

Sincerely, FLORIDA POWER CORPORATION 1

L0(+

W. P. Stewart Enclosure WPS/QBD/hw 4/2 E ^

"^' S 0\\

k0 cc:

G. T. Fairburn G. P. Beatty, Jr.

General Office 3201 Thirty fourtn street soutn. P.O. Box 14042, st. Petusburg. Florida 33733. 813-866-5151 b

o STATE OF FLORIDA COUNTY OF PINELLAS W. P. Stewart states that he is the Director, Power Production, of Florida Power Corporation; that he is authorized on the part of

. said company to sign and file with the Nuclear Regulatory Commission the information attached thereto; and that all such statements made and matters set forth therein are true and correct to the best of his knowledge, information and belief.

P

~

n

/) i{I(LLCCc1E h

-(-

W. P. Stewart Subscribed and sworn to before me, a Notary Public in and for the State and County above named, this 4th day of May, 1978.

.-,-~ -

~

Notary Public /

Notary Public, State of Florida at Large, My Comission Expires: July 25,1980 e

y

-