NRC-2018-000831 - Resp 2 - Interim (NRC Sources of Materials) Part 8 of 10
ML19319B316
Person / Time
Issue date: 11/13/2019
From:
NRC/OCIO
To:
Shared Package
ML19319B303 List:
References
FOIA, NRC-2018-000831
Download: ML19319B316 (6)


Text

Sources of Materials: Past NRC Harvesting and U.S.

Decommissioning Plants NRC Staff March 7, 2017

Metals

  • Examples of harvested materials used in NRC research programs:

- Boral from Zion

- SS plate and welds from Zorita

  • 304SS ranging from <1 to 50 dpa; SS weld up to 1 dpa

- PWSCC

  • Alloy 600 J-groove weld from Davis-Besse
  • Alloy 600 CRD nozzle from North Anna
  • Alloy 182/82 from VC Summer

- RPV

  • Shoreham, Midland 2

Electrical

  • Zion

- 4.16kV non-segregated bus duct

  • Used in NRC / OECD High Energy Arc Fault Testing
  • Bellefonte

- 8 Electrical enclosures

Recently Shutdown U.S. Plants Plant Design Size (MWt)

Years in Operation Shutdown Date Kewaunee W 2-loop 1772 39 2013 SONGS 2/3 CE 2-loop 3438 31/30 2013 Crystal River 3 B&W 2609 36 2013 Vermont Yankee BWR-4/Mark-1 1912 42 2015 Fort Calhoun CE 2-loop 1500 43 2016 4

Planned Shutdown U.S. Plants Plant Design Size (MWt)

Years in Operation Planned Shutdown Palisades CE 2565 47 2018 Pilgrim BWR-3/Mark-1 2028 47 2019 Oyster Creek BWR-2/Mark-1 1930 50 2019 Indian Point 2/3 W 4-loop 3216 48/46 2021 Diablo Canyon 1/2 W 4-loop 3411 40 2024-5 5

Additional Information from Plants

  • Point of Contact
  • Drawings and plant design information

- To understand location of components within plant

- Size and dimensions of components

  • Operating history

- Environmental information (e.g., temperature, fluence, humidity, pressure, etc.) for components of interest

  • Material information

- Fabrication records, CMTRs

  • Inspection records

- Components with known flaws 6