o8 STATE May 28, 1980 Docket No. 50-298 Nebraska Public Power District AITN: Mr. J. M. Pilant, Director-Licensing & Quality Assurance Post Office Box 499 Columbus, Nebraska 68601 Gu tlemen:
The a closed IE Information Notice is forwarded to you for information.
No written response to this Information Notice ic required.
If you have any questions related to the subject, please contact this office.
Sincerely, 0
, 10: L
" di 2
Karl V. Seyfrit' /.
Director
/
Enclosures:
1.
IE Informaticn Notice No. 80-22 2.
List of Recently Issued IE Information Notices cc:
L. C. Lessor, Superintendent Cooper Nuclear Station Post Office Box 98 Brownv111e, Nebraska 68321 l
S hb o
L80070.20 g p j
SSINS: 6870 Accessions No:
UNITED STATES 8005050059 NUCLEAR REGUI.ATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, DC 20555 IE Information Notice No. 80-22 Date:
May 28, 1980 Page 1 of 2 BREAKDOWNS IN CONTAMINATION CONTROL PROGRAMS Description of Circumstances Recent inspections at power reactors have revealed breakdowns in contamination control programs resulting in releases of radioactive materials to the unrestricted area and off-site environment by several different patbvays.
The first pathway was via disposal of supposedly clean trash in the nearby county sanitary landfill. High background radiation levels due to an onsite buildup of radioactive waste precluded adequate radiation surveys of clean trash prior to removal from the restricted area.
In addition, the surveys were being conducted by improperly trained personnel.
The result was the undetected disposal of radioactive material in the local sanitary landfill.
1 An NRC inspector observed the practice and confirmed his suspicions when he I
detected levels of radiation 10 to 20 times normal background levels at the landfill. Subsequent surveys by the licensee, the State, and the NRC revealed several other areas in the landfill with higher than normal dose rates.
Excavation by the liceasee revealed items with contamination levels up to 100 arem/hr contact reading. These items had been delivered with the clean trash from the plant and buried at the landfill.
A second pathway was identified to be through the sale by the licensee of scrap materials to salvage dealers in the surrounding area.
Several items with contamination Icvels in excess of the licensee's unrestricted area release limits were discovered to have been sold to these vendors. Maximum dose rates on these items did not exceed 1.0 mrem /hr. This condition evidently also resulted from the elevated background radiation levels within the plant and the practice of permitting unqualified persor.nel to conduct radiation surveys.
A third pathway was found during a recent NRC inspection.
An NRC inspector's rediation survey revealed soil contamination on site extending beyond the protected area fence. Radiation levels as high as 1.5 mrem /hr were measured on contact with the soil. The contamination is believed to be atmospheric fallout of particulate radioactivity which was exhausted from the plant stack during containment purge following explosive plugging of steam generator tubec. The steam generator manways were not covered and the purge system was not equipped with HEPA filters. The licensee's survey program did not include routine, periodic site and perimeter surveys.
IE Information Notice No. 80-22 May 28, 1980 Page 2 of 2 This IE Information Notice is provided as an early notification of a significant matter that is still under review by the NRC staff.
It is expected that recipi-ents will review the information for possible applicability to their facilities.
No specific action or response is requested at this time.
If NRC evaluations so indicate, further licensee actions may be required.
No written response to this IE Information Notice is required.
If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.
IE Information Notice No. 80-22 May 28, 1980 LISTING OF RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued To Notice No.
Issued 80-16 Shaft Seal Packing Causes 4/29/80 All power reactor Binding in Main Steam facilities in your Swing Check and Isolation Region with an OL or Valves CP 80-17 Potential Hazards Associated 5/5/80 All radiography With Interchangable Parts Licenses On Radiographic Equipment 80-18 Possible Weapons Smuggling 5/5/80 All power reactor Pouch facilities with an Operating License (OL), fuel fabrication and processing facilities and Materials Priority I licensees (processors and distributors) 80-19 NIOSH Recall of Ricircu-5/6/80 All holders of a lating-Mode (Closed Circuit) power reactor Operating Self-Contained Breathing License (OL), Research Apparatus (Rebreathers)
Reactor License, Fuel Cycle Facility License and Priority I Material License 80-20 Loss of Decay Heat Removal 5/8/80 All light water reactor Capability at Davis-Besse facilities holding Unit 1 While in a Refueling power reactor Operating Mode Licenses (OLs) or Construction Permits (cps) 80-21 Anchorage and Support of 5/16/80 All power reactor Safety-Related Electrical facilities with an Equipment OL or CP Enclosure