r.,
e
...LISADES NUCLEAR PLANT c-PROC 110 ti.p.6.2:
le.. s l
)
((
licalth Physics Procedure PACE 1 0F 2
REVIS10!! 3 TITLE.
INPLACE ilEPA AND CllARCOAL FILTER TESTING Contmers pa,nr e
DATE 12/29/76 1.0 PURPOSE To demonstrate' collection efficiency of accident ventilation filters.
2.0 REFERENCES
' o Technical Specifications Table 4.22, Item 11.
3.0 ACC$PTANCE CRITERIA The collection efficiency for each filter is 99% per appropriate section of Procedure NCS-375.
4.0 INITIAL CONDITIONS 1.-
Shift. Supervisor Approval Required 4/-4 Y[
Shift Supervisor Initials d
Date 2.
Radiation Uork Permit needed to enter or physically work on ventilation systems.
(f 5.0 PRECAUTIONS AND LIMITS Same as Acceptance Criteria.
6.0 ATTACIE4ENTS 1.
QA Ictter of revieu 4/4/75 2.
Nuclear Containment Systems certificate of qualification.
3.
Nuclear Containment Systems QA Manual, NCS-Ql, Rev. O.
'4.
Procedure for Inplace Testing of HEPA Filters and Iodine Absorbers, NCS-375 Rev. 1, 8/22/75 7.0 PROCEDURE 1.
Attach current instrument calibration data with Palisades Representative verfication to working copy of procedure.
- - > ~veuDo/2. ?coca.Dm16 NW9 g
2.
Do procedure NCS-375, Rev. 1, 8/22/75. 4 4
g gq
~
NOTE:
Actions taken to correct deficiencies should be recorded under
" Remarks". Where appropriate, the "as found" and "as left" values and/or conditions should be recorded also.
-If 3.
The llealth Physics Department will file uorking copy of II.P.6.27.
The Technical Superinterdent is to receive a copy of data sheets.
Booggog blY.
rn.w runn enni
-- z. u. = v : - :. u war a
so
- ge i
., 0,
PALISADES NUCLEAR PLANT
,, =,,
PROC 10 li.P.2.27 (h),'s
!!calth Physica Procedure PAGE 2 0F 2 q.o.:
TITLE. INPIACE !! EPA AND CilARCOAL FILTER TESTING REVIS10!! 3 r
Ccastimers Power DATE.1?./29/76 8.0 REVIEtt AND APPROVAL,
1.
Shift Supervisor notified of completion.
I shift Supervisor initials Date 2.
Ilealth Physicist approval.
IIcalth Physicist initials Date e
6
(
(
4 e
6
(
LOW:hw,i. 0 t.U F f
_._m
Mast.cr File Traininst SS
- \\,,
g,
lleal th Phyr.icir.t Shift Supervi.so rs Controlled Copics e
"?,
Rad Pro Supv.
Operations Supv.
_RMC Supv.
Maintenance Supt.
.i End Pro Office Chemical Eng.
I " "
JCLeuls PJIC Technician's Of fice.
SD$U[Il3[3 12/29/76 Respiratory Prograra 90'il5f o^*.' Associate llenlth Physicist g su. sect PROCEDURE (TOMeek) AUTi!0RIZATION I N TE RN A t. Comatsronotwcc INFORMATION COPIES:.RUSinderman i Associate IIcalth Physicist CEAxtell (JHart) REDeWitt (Training Coord. (Ridland The following (proc.edures) (partienr.xtfxpre.w3&nv) is/bT4 authorized to be utilized by the Plant Staff, taking into account plant conditions and other considerations as listed. PROCEDURE DESCRIPTION Procedure: Permanent Inplace HEPA and Charcoal Filter Testing Procedure Number H.P.6.27 Revision Munber 3 Date 12/29/76 Author GDMichie s Section All PRC Review Date 12/9/76 Revision 0 Author DJChinavare (RR-3 ,g v r r {c'A;. ,.=. t f' '-J v ' we!T t.GW s y,91b'@y\\'3 1 i'; l P Q9: t f.- } I l' . f.:S y7 t y c. v. l. 1 !,p,.s ' '",Q' * ',' . c. ...,,...c.. r :" '. i '..., b. r,. g. i.' 'h,I',,,*-).. ). '
- _.. }'
LJ I Q. ~ f . i N,,..,i n 4 ; . r. e...s..r.:...u ~ - G s. VEShockley Plant llealth Physicist i An ~ JGLewis Plant Superintendent Co*4ME01ND TOPY t. -}}