' APPENDIX A NOTICE'0F VIOLATION Public Service Electric and Gas Company Docket Nos. 50-354 50-355 This refers to the irspection conducted by representatives of the Region I (Philadelphia) office at the Hope Creek Generating Station, Units 1 and 2, Hancocks Bridge, New Jersey, of' activities authorized by NRC License Nos. CPPR-120 and 121.

During this inspection, conducted on January 14-17, 1980, the following apparent item of noncompliance was identified:

10 CFR 50 Appendix B Criterion XVI states, in part,' that:

" Measures shall be established to assure that conditions adverse to quality... are promptly identified and corrected."

Section 16.2.2.3 of Chapter 16 of the PSAR states, in part, that:

"PSE&G requires its. contractors to assume primary responsibility for establishing and implementing QA/QC programs within their scope of activity. - These QA/QC programs are contractually required to meet Appendix B of 10 CFR 50..."

Contrary to the above, as of January 17, 1980, adequate measures were not estab-lished and implemented in the quality assurance programs of Public Service Electric and Gas Company and its contractors to ensure that conditions adverse to quality are corrected promptly. As a result, identified deficiencies in the Unit 1 personnel and equipment access hatches were not corrected promptly and adequate measures were not taken to prevent further deterioration of the condition of those hatches.

This item is an infraction.

8006250Qgj

-