h DUKE POWER COMPANY COCONEE UNIT 2 7,

o Report No.: RO-270/76-16 Report Date: January 26, 1977

' Occurrence'Date_: December 27, 1976 Oconee Unit 2, Seneca, South Carolina Facility:

Reactor operation exceeded the error adjusted Identification of Occurrence: power imbalance limit Conditions Prior to Occurrence: Unit at 100 percent full power Description of Occurrence:

27, 1976'at approximately 0600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br />, the computer program which On December The reactor calculates the reactor power imbalance was discovered inoperable.

power imbalance is measured both by the incore and out-of-core detector systems Because of and is normally calculated and displayed by the plant computer.

the better accuracy of the incore system, the incore system is preferred for When the computer imbalance measurement when the plant computer is available.

imbalance program became inoperable, it became necessary to perform a hand calculation of the reactor imbalance from the out-of-core detector indication.

Although the imbalance was within the error adjusted incore system limits at the time the computer program became inoperabic, subsequent hand calculations utilizing the out-of-core detector readings indicated that the imbalance was outside the error-adjusted out-of-core system limits, mainly due to larger Action was taken to error-adjustment factors for the out-of-core system.

reduce the imbalance to within the error-adjusted out-of-core system limits; however, as required by Technical Specification 3.5.2.6, a power reduction was initiated approximately two hours after the loss of the incore imbalance The imbalance was returned within the out-of-core error-adjusted indication.

imbalance limits at 0812 hours0.0094 days <br />0.226 hours <br />0.00134 weeks <br />3.08966e-4 months <br /> on December 27, 1976.

Apparent Cause of Occurrence:

This occurrence.resulted from a sof tware lockup on the Unit 2 computer which caused the loss of the computer _ program for calculating reactor power imbalance.

Analysis of Occurrence:

Technical Specification Figure 3.5.2.3B1 provides a limit for reactor power imbalance versus reactor power level to prevent the maximum linear heat rate The existence of statis-from exceeding ~ the values used in the LOCA analysis.

tical and _instruaent errors associated with the measurement of reactor power imbalance makes it necessary to operate within an error-adjusted power imbalance envelope'in order to assure that the Technical Specification limit is not In this incident, the reactor was operated for two actually being exceeded.

hours outside the error-adjusted out-of-core power imbalance limits, and,

'therefore, it is possible that the limits specified in Technical Spec fica-

. tion Figure 3.5.~2.3B1 were exceeded.

8001140

7 v-

. b _..,,.

+

r 4

s

. 7. ;.

. e.'

. Ilowever, the Bases for. Technical Specification _'t.5.2 state that all of the power distribution parameters (quadrant tilt, rod position limits and im-balance) must be at their limits while simultaneously all other engineering and unc'ertainty factors are also at their limits to produce t'ae maximum

. allowable heat rate. In this incident, the maximum-occurrirg quadrant tilt was 0.3% as compared with the operating limit of 3.4% permi'.ted by Technical Specification 3.5.2.4a.

Also,' the control rods were' maintained well within

.the normal-maneuvering band.

For the.=

reasons, it is concluded that the health and safety of the public was not affected by this incident.

Corrective Action:

-Reactor power was reduced in a timely manner to a level where the measured imbalance was within sIecified limits.

The computer imbalance calculational program was restored to.an operable status and was verified to be functioning correctly.