$ v$
/
1 6
E G 1974 H. D. Thornburg, Chief, Field Support and Enforcowent Branch, RD DUEF. POWER COMPANY - OCONEE 1 AND 2. INTENT OF TECHNICAL SP j
3.2.2, RO:II MEHORANDUM DATED JULY 15, 1974 (F0#93HI)
In accordance with your request in PU 93H1, we have reviewed the subject nectorindum and have the following cocunents:
i Eased on a review of Facility Technical Specifications for Unita 1 and 2, we have concluded that the Concentrated Boric Acid Storage Tank System (CBAST) at a shutdown unit can be used to satisfy the requiras.ents of paragraph 3.2.2. of the i
j technical specifientions at the operatint unit provided:
1.
The. activity at the operating unit which required an auditional CBAST system had been proplanned.
1 2.
The activity at the operating unit, i.e., maintenance, testing, etc., will be perfomed in accord =ce with approved proceduros that require licensee personnel to i
verify that the shutdown unit CBAST system is aligned r
for the operating unit prior to initiating the activity.
3.
The procedures have been reviewed and approved as required t
by the technical specifications.
t
'!c believe this completes the action requested by IV 93Hl.
a Orig:# Lgru in F.f.Nolen J. H. Sniezek, Acting Chief Facility Inspection Branch Directorate of Regulatory Operations t
i t
cc:
B. H. Grier, R0 (CD 548)
L. McDonough, DL l
C. Upright, RO:II e
,1 l
RO: FIB
[ RO: FIB kg orrec e >
FNolan:1b JHSnieg[
l j:
7/25/75 7/25/74 Foran ABc.)lt (Rev. !P.53) ARCM 0240 ll',
4 wI W u. s. nova==nesur reinvene orrects sere.sas.see E
8001070 [ b
@