e 3

O Oconen Unit 1 v

UNIT 5/7/75 DATE DOCKET NO.

50-269 OPERATING STATUS 1.

REPORTING PERIOD:

April 1, 1975 THROUGH April 30, 1975 720 HOURS IN REPORTING PERIOD:

2.

CURRENTLY AUTHORIZED POWER LEVEL (MWth e MAX. DEPENDABLE CAPACITY 4MWe NET, 871 3.

LOWT.ST POWER LEVEL TO WHICH SPECIFICALL) RESTRICTED (IF ANY:(MWe. NET):

None 4.

REASONS FOR RESTRICTION (IF ANYl:

THIS CUMULATIVE REPORTING Pl RIOD YR TO DATE TO DATE 719.1 1297.8 11098.3_

S.

HOURS REACTOR WAS CRITICAL.

6.

REACTOR RESERVE SHUTDOWN HOLRS 703.7 1129.6 9384.0 7.

HOURS GENERATOR ON LINE.

8.

UNIT RESERVE SHUTDOWN HOURS -.

9.

GROSS THERMAL ENERGY 1547088 2313165 20550675 GENERATED tMWH) 10.

GROSS ELECTRICAL ENERGY 545140 809730 7128430 GENERATED (MWH) 11.

NET ELECTRICAL ENERGY GENERATED (MWH) 517867 747784 6700Rn1 12.

REACTOR AVAILABILITY F ACTOR (13 99.9 45.1 70.7 97 7 14 9 9A A 13.

UNIT AVAILABILITY F ACTOR (2) 82.6

?Q A AA 9 14.

UNIT CAPACITY F ACTOR (3) 2.3 60.7 23.6 15.

UNIT FORCED OUTAGE RATE (4).

16.

SHUTDOWNS SCHEDULED TO BEGIN IN NEXT 6 MONTHS (STATE TYPE.D ATE. AND DUR ATION OF EACH):

17.

IF SHUT DOWN AT END OF REPORT PERIOD.ESTIM ATED DATE 01 STARTCP:

18.

UNITS IN TEST STATLS (PRIOR TO COMMERCIAL OPERATION) REPORT THE FOLLOWING:

DATE LAST D4TE FORECAST ACH'IEVED INITIA L CRITICALITY INITIAL ELECTRIC AL POWER GENE RATION COMMERCIAL OPERATION X 100 (1) REACTOR AVAILABILITY FACTOR

=

X 100 (2)

UNIT AVAILABILITY FACTOR

=

NFT EllTTRIC%L POWFR GFNE R ATFD (3) UNIT CAPACITY FACTOR

=

MAX. DLPENDABLL CAPAt ITY iMWe NET) X HOUR ; tN REPORI'ING PERIOD (4)

UNIT FORCED OUTAGl*. R ATE LOURS GL R TR N LINE + FORLF D OUT LGE HOURS 7912180 78 1

DOCKET NO. 50-269 UNIT oconee Unit _1 DATE 5/7/75 AVERAGE DAILY UNIT POWER LEVEL MONTH April, 1975 AVERAGE D AILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY (MWe-net)

DAY (MWe-net) 854 723 17 1

855 692 18 2

857 3

514 19 857 4

607 20 5

536 21 856 6

538 22 552 593 23 257 7

767 8

517 24 790 527 25 9

525 26 849 10 714 27 853 11 778 28 852 12 844 29 853 13 14 851 30 854 856 31 15 16 856 DAILY UNir POWER LEVEL FORM INSTRUCTIONS On this foim, list the average daily unit power level in MWe-net for each day in the reporting month.

Compute to the nearest whole megawatt.

These figures will be used to plot a graph for each reporting month. Note that by using maximum dependable capacity for the net electrical rating of the unit, there may b measions when the d9ily average power level exceeds the 100To line (or the restricted power level Uncl. In such c.tses, the average daily unit power output sheet should be footnoted to explain the apparent anomaly.

DdCKET NO.

50-269 Oconee Unit 1

~

UNIT SHUTDOWNS UNIT NAMli DATli May 7, 1975 RIiPORT MONTil April, 1975 TYPE METHOD OF F FO9CED DURATION SHUTTING DOWN I

NO.

DATE S SCiniDULED (HOURS)

REASON (O THE REACTOR (2)

CORRECTIVE ACTIONS / COMMENTS 6

750422 F

7.05 A

3 Integrated Control System malfunction 7

750423 F

9.25 G

3 Unit tripped during transient (1) REASON (2) METilOD A -EQUIPMENT F ALLURE (EXPLAIN) 1-MANUAL B-MAINT. OR TEST.

2-MANUAL C-RLi'UELING SCRAM D-REGULAlORY RESTRICTION 3-AUTOM ATIC

)

E-OPERATOR TRAINING AND SCRAM LICLNSE EXAMINATION F-ADMINISTRATIVE G-OPERAllONAL ERROR (LXPLAIN)

Il-0TilLR (EXPLAIN)

SUMMARY

.