Forwards IE Bulletin 76-06, Diaphragm Failures in Air Operated Auxiliary Actuators for Safety Relief Valves. Action Required
ML19317E139
Person / Time
Site: Oconee  
Issue date: 07/21/1976
From: Moseley N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Parker W
DUKE POWER CO.
References
NUDOCS 7912160011
Download: ML19317E139 (1)


Text

'*s m

ts::i; n.

..n

3. f.-

v TJL'.L;.i,.

' F + '. U ' : L.. '.' CD.

41:,.:

1t.

11 2 A s i.... t t ?.t :

r i, r1 w.

Sv!at 013

  1. [

.t A : t ; u r.

A T i.;

  • i a, JUL 21 W6 In,.'

0-i.e. e r 'l.o:

1 L: II G.F.

5_

0 i

50-287 Duke Power Cc::pany ATTU:

M. Willia:: 0. Parker, Jr.

Vice President of Stea:: Production h22 South Church Street P. O. Box 2178 Charlotte, North Carolina 282h2 G c.: c ler.e n :

Enclo :ed in 17 Cul' 'tia 'Ja. 76-C6 h!.ch requiras cetic" by you.fith re';a rd to :rour pot.cr rer. : Lar f r.c tli c:-(ie.:) uith c.: cper: ::,

license.

Sh uld you ha.'e q:.'ztioer rte.1 :.. :

C. '

1 illetin or the acti.

rec,oired of / u, pl-t-e cen t..c l t-offico.

S '.nce r el y,

iorr.cn C. I'.
ley Director Enclas "es:

1: null. tiu ::o. 76 Dicphr.

Failure In Air Operat

.it xilL.r:- Ac tuntor-For Saf c Ly Ilcli ef Val.>es

.T912160O//

p

~

v NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D. C.

20555 IE Bulletin No. 76-06 DATE:

July 21, 1976 rage 1 of 3 DIAPHRAGM FAILURES IN AIR OPERATED AUXILIARY ACTUATOPS FOR SAFETY / RELIEF VALVES.

DESCRIFTION OF CIRCUMSTANCES:

On July 8,1976, Vermont Yankee reported that during a scheduled refueling outage surveillance test on their Target Rock valves, the auxiliary air actuator was found to be inoperable on three of the four valves.

The licensee reported that investigation disclosed that the actuator diaphragms, composed of dacron fabric reinforced silicone rubber, had been degraded by excessive hect.

The excessive heat is attributed to the fact that, contrary to the valve manuf acturer's installation instructions, thermal The insulation had been applied to the pneumatic actuator.

licensee further reported that the valve in which the diaphragm was found not to be degraded, was installed in the direct path of cooling air discharge from the venti-lation system, thus receiving supplementary cooling.

Elastomeric materials such as the subject diaphragms are known to have finite service life and to be degraded by excessive temperatures; however, thic is the first reported instance of degradation of this component.

This event has particular safety significance, since failure of the diaphragms defeats the function of the Automatic Depras-surization System.

In recognition of this situation, the NRR Division of Operating Reactors conducted a celephone survey on July 16, 1976, of selected HRR operating facilities.

C$uf M

Mo Y1o o/32.

  • O.

IE Bulletin No. 76-06 DATE: July 21, 1976 Page 2 of 3 ACTION TO BE TAKEN BY LICENSEE:

All operators of BWR and PWR reactor facilities with operating licenses are to take the following actica:

1.

Determine that the insulation installed on safety related diaphragm operated relief valves in high temperature fluid systems is in accordance with the current recommendations of the valve vendor, i.e. that there is no thermal insulation on the air actuator.

2.

Ensure that the procedures used for the disassembly and inspection of these valves, as required by the Technical Specifications, specifically include in-spection of the subject diaphragms to determine that no significant deterioration of the diaphragm material has occurred.

3.

Ensure that the vendor's recommended service life and shelf life for the diaphragms is not exceeded for the environmental conditions to which the material is exposed.

4.

A report of you* plans and schedules for accomp-lishing the above actions should be eubmitted with-in 10 days after receipt of this Bulletin.

Edr facilities already curveyed b'; NRK: DOR, this report should confirm information reported orally.

5.

The NRC Regional Office should be promptly informed, within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, of any adverse findings resulting from your inspection and/or review of the subject diaphragms or their application.

I#

6.

Within 20 days after completion of the actions described in Item 4 above, report the results, in-cluding for any valves found to have degradation of diaphragms, the make, type, size, diaphragm material, and service (system) application.

~

IE Bulletin No. 76-06 DATE:

July 21, 1976 Page 3 of 3 Reports should be submitted to the Director of the NRC Regional Office and a copy should be forwarded to the NRC Office of Inspection and Enforcement, Division of Reactor Inspection Programs, Washington, D. C.

20555.

Approval of NRC requirements for reports concerning possible generic problems has been obtained under 44 U.S.C 3152 from the U. S. General Accounting Office.

[