ML19317D712

From kanterella
Jump to navigation Jump to search
Forwards RCS Incident Rept in Response to NRC Requests. Identifies Sequence of Events & Extent of Damage Associated W/Loose Parts Resulting from Failure of Several Reactor Internal Components During Hot Functional Testing of Unit 1
Date released: 11/27/2019 Download: ML19317D712


Ro:On 720311,several Reactor Components Failed During First Phase of Hot Functional Testing Program.Loose Parts from Failures Caused Extensive Damage to Tube Ends & to Tube Sheet Welds in Steam Generator Upper Head a
ML19317D714
Person / Time
Site: Oconee 
Issue date: 04/04/1972
From: Thies A
DUKE POWER CO.
To:
References
Download: ML19317D714 (7)
Forwards RCS Incident Rept in Response to NRC Requests. Identifies Sequence of Events & Extent of Damage Associated W/Loose Parts Resulting from Failure of Several Reactor Internal Components During Hot Functional Testing of Unit 1
ML19317D711
Person / Time
Site: Oconee 
Issue date: 04/04/1972
From: Thies A
DUKE POWER CO.
To: MORRIS P A
US ATOMIC ENERGY COMMISSION (AEC)
References
Download: ML19317D711 (1)