ML19317D665

From kanterella
Jump to navigation Jump to search
Discusses Conditions for Acceptable Use of Plant Simulators in Operator Training Programs
ML19317D665
Person / Time
Site: Oconee  
Issue date: 10/03/1974
From: Collins P
US ATOMIC ENERGY COMMISSION (AEC)
To: James Smith
DUKE POWER CO.
References
NUDOCS 7912060895
Download: ML19317D665 (2)


Text

\\

hl # (

~

r

.o UNITED STATES 5

ATOMIC ENERGY COMMISSION

~

y q

q* '

wassmoros.o.c. ous

,l

OCT 3 574 Docket No 50- 269/270 Duke Power Company ATTN: Mr. J. Ed Smith, Superintendent Oconee Nuclear Station P.O. Box 1175

' Seneca, South Carolina 29678 Gentlemen:

Nuclear power plant simulators were introduced into operator training programs in 1969. In the time since their introduction the Operator Licensing Branch has carefully evaluated their role in the training programs. Based on this evaluation the Operator Licensing Branch has approved increased use of appropriate simulators in the admin-istration of the operator licensing program.

First, the applicants seeking licenses prior to criticality at a facility were given appropriate credit for participating in training programs that utilized acceptable simulators. Then, training programs were approved that utilized simulators for facilities after which the simu-ulators were modeled. Further, the use of appropriate simulators was permitted in meeting certain requirements of the operator requalifi-cation programs.

We have now determined that it is acceptable to use nuclear power plant simulators in determining the qualifications of individuals who apply for licenses after initial criticality.

Presently, applicants for licenses, after the facility has achieved criticality must participate in training programs that include, at least, two reactor startups at the facility for which N. seeke ~a license to meet the eligibility requirements to sit for an examination. In addition, applicants must perform a startup of the r? actor as part of the

)

operating test.

The Operator Licensing Branch will consider training program.s that utilize appropriate nuclear power plant simulators for startup ex-perience for meeting the startup eligibility requirements to sit for examination. In addition, a reactor startup will not be required as part of the operating test, providing that appropriate certification regarding an individual's ability to manipulate the controls is contained in his application.

79120@

d5

e

, : -l A

.1 1 OCT 3 1974 In order for the applicant to be eligible for this alternate program, the following requirements must be met.

1.

The applicant has manipulated the controls of his reactor facility during five significant reactivity changes, which may, or may not, include reacter startups.

2.

The applicant has participated in an AEC-approved training program that includes training at a nuclear power plant simulator, and 3.

The application contains a certification from the simulator training center attesting to the applicant's:

a.

ability to manipulate the controls and keep the reactor under control during a reactor startup, b.

ability to predict instrument response and use the instrumentation during a reactor startup, c.

ability to follow the facility startup procedure and d.

ability to explain alarms and annunciators that may occur during this operation.

The simulators used in the programs must meet the present require-ments for simulators enumerated in Paragraph 3.e., Appendix A of 10 CFR Part 55, namely, that the simulator reproduce the general opera-ting characteristics of the facility involved, and the arrangement of instrumentation and controls of the simulator is similar to that of the facility involved.

l The present procedure for training and examining will be continued for I

those facilities who do not desire to use the alternate procedure des-cribed above.

I hope this information will be of use to you. If you have any questions, please contact me.

i Sincerely, f Jhl Paul F. Collins, Chief Operator Licensing Branch Directorate of Licensing

-~

_