DUKE POWER COMPANY OCONEE UNIT 2 i
i t
l 1
Report No.: UE-270/75-13 Report Date:' August 27, 1975 i
Event Date: ; July 31, 1975 1
Facility:_ Oconec Unit 2, Seneca, South Carolina One train of Reactor Building Spray inadvertently l
Identification of Event:
taken out of service Conditions Prior to Event: Unit at 100 percent full power i
f I
Description of Event:
1 On July 31, 1975, the Reactor Building Spray Engineered Safeguards Test was performed on Oconec Unit 1.
In the performance of the test, the l
Control Operator instructed the Utility Operator to open the breaker for valve 1BS-2.
A Utility Operator's trainee inadvertently opened the Unit 2 l
breaker for valve 2BS-2, thereby removing one train of Reactor Building 4
The breaker to 2BS-2 was opened l
spray from service on an operating unit.
f approximately 20 seconds until the Utility Operator acknowledged a Unit 2 l
alarm and had the trainee close the breaker for valve 2BS-2.
Designation of Apparent Cause of_ Event:
The apparent cause of this event was operator error in that the trainee was The not adequately supervised and operated the breaker on the wrong unit.
breakers were clearly identified as to valve number and unit number.
Analysis of Event:
This incident resulted in one train of Reactor Building spray being inoperable for approximately 20 so. nds. The redundant train of building spray and the j
entire Reactor Building Cooling System were operabic during this time and would have furttioned properly is needed.
It 13 concluded that the health and safety of the public was not affected.
Corrective Action:
^
The personnel involved in this incident have been reminded of the importance I
The of assuring that they properly identify components prior to operation.
Shift Supervisor is discussed with personnel the necessity for proper
". cations and proper supervision of trainees to avoid future occurrences.
comst.