ML19316A548

From kanterella
Jump to navigation Jump to search
Requests Addl Info within 30 Days Re Util 780602 Request to Use Substitute Surveillance Tendon in Containment Structure
ML19316A548
Person / Time
Site: Oconee 
Issue date: 08/01/1978
From: Reid R
Office of Nuclear Reactor Regulation
To: Parker W
DUKE POWER CO.
References
NUDOCS 8001100763
Download: ML19316A548 (3)


Text

..

DISTRIBUTION:

August 1, 1978 Dockey RC-FDR L PDR ORB #4 Reading Docket

o. 50-287 VStello BGrimes/TCarter OELD OI&E(3)

RWReid Duke Power Company MFairtile ATTH: Mr. William O. Parker, Jr.

RIngram Vice President - Steam DEisenhut Production TAbernathy P. O. Box 2178 JBuchanan 422 South Church Street ACRS(16) l Charlotte, North Carolina 28242 Gray file 1

Gentlemen:

We are currently reviewing your submittal of June 2,1978, in regard to a request to use a substitute surveillance tendon in the Oconee 1

Huclear Station Unit No. 3 containment structure. We find that we need additional infomation so that we can continue our review of this proposal.

It is requested that you provide the infomation identified in the enclosure to enable us to complete our review. Kindly submit three signed originals and 37 additional c6 pies within 30 days of receipt of this letter.

Sincerely.

f Robert W. Reid, Chief Operating Reactors Branch f4 Division of Operating Reactors

Enclosure:

Request for Additional Infomation cc w/ enclosure: See next'page g,

\\M 1sa r

c g w

~

fb!S I

YdA W 6blM7

[

ORB #4: DOR C-0RB#d:JdR

\\-

o,,,s.,

MFairtile:dn lRWReidI.*'

~

3 0 m Jy g/ / /78 g// /78:

^

~

O ua s.oovsawurwr raswTime orrics soye-sam

(

NRCICRM 318 (9 76) NRCM 0240 8101 r oo 7t3 to

1 Duke Power Company I

cc: Mr. William L. Porter i

Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, florth Carolina 28242 J. Michael McGarry, III Esquire DeBevoise & Liberman 700 Shoreham Building 806-15th Street, NW.,

Washington, D.C.

20005 Oconee Public Library j

201 South Spring Street Walhalla, South Carolina 29691 i

6 6

e 4

4 6

e e

e 4

e 9

+

fe'd f,* L

-. a

.,o ENCLOSURE REQUEST FOR ADDITIONAL IftFORMATION DUKE POWER COMPANY - OCONEE STATION (DOCKETS # 50-269; 50-270; 50-287)

REVIEW OF REACTOR CONTAINMENT BUILDING -

REQUEST FOR CHANGE IN TECHNICAL SPECIFICATION 4.4.2 SUBSTITUTION OF SURVEILLANCE TENDON 2028 Indicate whether any damage has been done to the concrete, anchor hardware or the conduit (also trumpet) in the vicinity of/or adjacent to, the 1.

damaged tendon 2D28.

Describe the procedure which will be used in installing the new tendon replacing the broken tendon 2028 and especially to what level o 2.

I it will be tensioned.

has to participate in load sharing with the existing tendons, during a postulated LOCA.

Since the total number of surveillance tendons is prescribed by the R. G.1.35 and the Technical Specifications, indicate what surveillance 3.

tendon will be substituted for the broken 2028.

Provide the results of wire inspection and testing for one wira in the 4.

broken tendon 2028, as prescribed in the Technical Specification.

i 1

)

r f'

-