ML19312E207
ML19312E207 | |
Person / Time | |
---|---|
Site: | Brunswick ![]() |
Issue date: | 05/27/1980 |
From: | Utley E CAROLINA POWER & LIGHT CO. |
To: | |
Shared Package | |
ML19312E208 | List: |
References | |
NO-80-783, NUDOCS 8006030470 | |
Download: ML19312E207 (2) | |
Similar Documents at Brunswick | |
---|---|
Category:OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING
MONTHYEARBSEP-99-0126, Application for Amend to License DPR-71,revising TS 2.1.1.2 to Remove Note That Limits Use of MCPR Safety Limit Values to Cycle 12 Operation1999-09-28028 September 1999
[Table view]Application for Amend to License DPR-71,revising TS 2.1.1.2 to Remove Note That Limits Use of MCPR Safety Limit Values to Cycle 12 Operation BSEP-98-0190, Application for Amends to Licenses DPR-62 & DPR-71,deleting Various License Conditions,Making Editorial Changes & Providing Clarifying Info1998-10-27027 October 1998 Application for Amends to Licenses DPR-62 & DPR-71,deleting Various License Conditions,Making Editorial Changes & Providing Clarifying Info BSEP-98-0165, Application for Amends to Licenses DPR-62 & DPR-71,revising TS 5.2.2.f to Require Operations Manager or Assistant Operations Manager to Hold SRO License1998-08-17017 August 1998 Application for Amends to Licenses DPR-62 & DPR-71,revising TS 5.2.2.f to Require Operations Manager or Assistant Operations Manager to Hold SRO License BSEP-98-0095, Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-14331998-04-24024 April 1998 Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433 BSEP-98-0037, Application for Amends to Licenses DPR-62 & DPR-72,revising Basis for Removing Suppression Chamber Temp Water Temp Monitoring Instrumentation Requirements1998-04-0909 April 1998 Application for Amends to Licenses DPR-62 & DPR-72,revising Basis for Removing Suppression Chamber Temp Water Temp Monitoring Instrumentation Requirements BSEP-98-0049, Application for Amends to Licenses DPR-71 & DPR-82 to Modify TS 3.5.3.1 & Associated Bases Section 3/4.5.3.1,revising Specified Total Volume of Condensate Storage Tank from 150,000 Gallons to 228,200 Gallons1998-04-0303 April 1998 Application for Amends to Licenses DPR-71 & DPR-82 to Modify TS 3.5.3.1 & Associated Bases Section 3/4.5.3.1,revising Specified Total Volume of Condensate Storage Tank from 150,000 Gallons to 228,200 Gallons BSEP-98-0062, Suppl to Application for Amend to DPR-71,revising Safety Limit Min Critical Power Ratio Ref in TS 2.1.2 from 1.10 to 1.09 for Two Recirculation Loop Operation & to 1.10 for Single Recirculation Loop Operation for Fuel Cycle 121998-03-27027 March 1998 Suppl to Application for Amend to DPR-71,revising Safety Limit Min Critical Power Ratio Ref in TS 2.1.2 from 1.10 to 1.09 for Two Recirculation Loop Operation & to 1.10 for Single Recirculation Loop Operation for Fuel Cycle 12 BSEP-98-0056, Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved TS as Contained in Rev 1 of NUREG-14331998-03-13013 March 1998 Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved TS as Contained in Rev 1 of NUREG-1433 BSEP-98-0036, Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-14331998-02-26026 February 1998 Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433 BSEP-98-0034, Application for Amend to License DPR-71,revising SLMCPR Referenced in TS 2.1.2 from 1.10 to 1.09 & Deleting Document Referencd in TS 6.9.3.2.c.Proprietary & non-proprietary GE Info,Encl.Proprietary Info Withheld1998-02-23023 February 1998 Application for Amend to License DPR-71,revising SLMCPR Referenced in TS 2.1.2 from 1.10 to 1.09 & Deleting Document Referencd in TS 6.9.3.2.c.Proprietary & non-proprietary GE Info,Encl.Proprietary Info Withheld BSEP-97-0506, Suppls to 961101 Application for Amend to TS to Allow Full Implementation of BWROG Enhanced Option I-A Reactor Stability long-term Solution.Suppl Expands Note in LCO 3.3.1.1,Table 3.3.1-11997-12-18018 December 1997 Suppls to 961101 Application for Amend to TS to Allow Full Implementation of BWROG Enhanced Option I-A Reactor Stability long-term Solution.Suppl Expands Note in LCO 3.3.1.1,Table 3.3.1-1 BSEP-97-0475, Application for Amends to Licenses DPR-71 & DPR-62,adding Footnote to Surveillance Requirement (SR) 4.8.1.1.2.d to Allow Performance of SR 4.8.1.1.2.d.1,SR 4.8.1.1.2.d.4 & SR 4.8.1.1.2.d.5 in Operational Condition 1 Through 51997-11-0606 November 1997 Application for Amends to Licenses DPR-71 & DPR-62,adding Footnote to Surveillance Requirement (SR) 4.8.1.1.2.d to Allow Performance of SR 4.8.1.1.2.d.1,SR 4.8.1.1.2.d.4 & SR 4.8.1.1.2.d.5 in Operational Condition 1 Through 5 BSEP-97-0454, Application for Amends to Licenses DPR-71 & DPR-62,revising Design Basis Qualification Requirements for CREVS & CREVS Instrumentation,For Limited Period of Time1997-11-0606 November 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Design Basis Qualification Requirements for CREVS & CREVS Instrumentation,For Limited Period of Time BSEP-97-0397, Application for Amends to Licenses DPR-71 & DPR-62,revising Proposed Terms in TSs 4.0.1 & 4.0.3 to Reflect Existing TS Terminology,Per GL 87-091997-11-0404 November 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Proposed Terms in TSs 4.0.1 & 4.0.3 to Reflect Existing TS Terminology,Per GL 87-09 BSEP-97-0458, Application for Amends to Licenses DPR-71 & DPR-62,revising Description of Control Rod Assemblies,Per Description Contained in NUREG-1433,Rev 11997-10-29029 October 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Description of Control Rod Assemblies,Per Description Contained in NUREG-1433,Rev 1 BSEP-97-0419, Application for Amends to Licenses DPR-71 & DPR-62,revising Certain Instrumentation Allowable Values,Per NUREG-1433,Rev 11997-10-28028 October 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Certain Instrumentation Allowable Values,Per NUREG-1433,Rev 1 BSEP-97-0445, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising SRs to Remove Allowable Humidity & Temperature Testing Ranges for Charcoal Adsorber1997-10-28028 October 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising SRs to Remove Allowable Humidity & Temperature Testing Ranges for Charcoal Adsorber BSEP-97-0443, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433.Rev a to Improved TS & Revised Responses to 970808 & 970911 RAIs Also Encl1997-10-13013 October 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433.Rev a to Improved TS & Revised Responses to 970808 & 970911 RAIs Also Encl BSEP-97-0359, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Labels for Coordinates of TS Figures 3.4.6.1-1, 3.4.6.1-2,3.4.6.1-3a & 3.4.6.1-3b as Pressure (Psig) & Temp (F)1997-08-27027 August 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Labels for Coordinates of TS Figures 3.4.6.1-1, 3.4.6.1-2,3.4.6.1-3a & 3.4.6.1-3b as Pressure (Psig) & Temp (F) BSEP-97-0319, Application for Amends to Licenses DPR-62 & DPR-71,approving Method of Transferring Spent Fuel Shipping Cask1997-08-0606 August 1997 Application for Amends to Licenses DPR-62 & DPR-71,approving Method of Transferring Spent Fuel Shipping Cask BSEP-97-0277, Application for Amends to Licenses DPR-62 & DPR-71, Clarifying TS 4.0.5.f Re Use of NRC Staff Approved Alternatives to Recommendations of GL 88-01, NRC Staff Position of IGSCC in BWR Austenitic Stainless Steel Piping1997-07-25025 July 1997 Application for Amends to Licenses DPR-62 & DPR-71, Clarifying TS 4.0.5.f Re Use of NRC Staff Approved Alternatives to Recommendations of GL 88-01, NRC Staff Position of IGSCC in BWR Austenitic Stainless Steel Piping BSEP-97-0315, Application for Amends to Licenses DPR-62 & DPR-71,revising Tech Specs 5.2.2.b & 5.4.2 Re Containment & RCS Design Features1997-07-18018 July 1997 Application for Amends to Licenses DPR-62 & DPR-71,revising Tech Specs 5.2.2.b & 5.4.2 Re Containment & RCS Design Features BSEP-96-0337, Application for Amends to Licenses DPR-62 & DPR-71,updating TS 3.6.1.6 to Support Upgrade to Containment Average Air Temp Limit Associated W/Conversion to Improved Tss.Encl Proprietary Rept & TSs Withheld1997-06-12012 June 1997 Application for Amends to Licenses DPR-62 & DPR-71,updating TS 3.6.1.6 to Support Upgrade to Containment Average Air Temp Limit Associated W/Conversion to Improved Tss.Encl Proprietary Rept & TSs Withheld BSEP-97-0222, Application for Amends to Licenses DPR-71 & DPR-62,revising Action Statements a.1 & a.2 of TS 3/4.4.5 by Reducing Max Allowed Reactor Coolant Specific to Activity1997-05-23023 May 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Action Statements a.1 & a.2 of TS 3/4.4.5 by Reducing Max Allowed Reactor Coolant Specific to Activity BSEP-97-0168, Application for Amends to Licenses DPR-71 & DPR-62,revising Surveillance Requirements to Require Testing of Control Room Emergency Ventilation Sys Charcoal & Revising Acceptance Criteria for Subject Charcoal Testing1997-04-30030 April 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Surveillance Requirements to Require Testing of Control Room Emergency Ventilation Sys Charcoal & Revising Acceptance Criteria for Subject Charcoal Testing BSEP-97-0144, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Tech Specs 3.0 & 4.0 & Respective Bases for Sections to Incorporate Guidance Contained in NRC GL 87-091997-04-14014 April 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Tech Specs 3.0 & 4.0 & Respective Bases for Sections to Incorporate Guidance Contained in NRC GL 87-09 BSEP-97-0135, Application for Amends to Licenses DPR-71 & DPR-62,revising Requirements for Instrumentation Response Time Testing Associated W/Rps,Isolation Actuation Sys & ECCS1997-04-11011 April 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Requirements for Instrumentation Response Time Testing Associated W/Rps,Isolation Actuation Sys & ECCS BSEP-97-0125, Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time1997-03-27027 March 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time BSEP-97-0120, Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time1997-03-24024 March 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time BSEP-97-0012, Application for Amends to Licenses DPR-71 & DPR-62 to Incorporate New TS Which Applies to Condenser Vacuum Pump Isolation Instrumentation1997-03-0505 March 1997 Application for Amends to Licenses DPR-71 & DPR-62 to Incorporate New TS Which Applies to Condenser Vacuum Pump Isolation Instrumentation BSEP-96-0447, Application for Amends to Licenses DPR-71 & DPR-62,revising Minimum & Maximum Values of Pressure Suppression Pool Water Vols Contained in TS 3.6.2.1.a.1 & Corresponding Bases1997-01-15015 January 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Minimum & Maximum Values of Pressure Suppression Pool Water Vols Contained in TS 3.6.2.1.a.1 & Corresponding Bases BSEP-96-0344, Application for Amends to Licenses DPR-62 & DPR-71,revising P-T Limits Curves Currently Located in Units 1 & 2 TSs & Deleting Current 8,10 & 12 Effective Full Power Yr Hydrostatic Test pressure-temp Limit Curves to Add New Ones1997-01-0707 January 1997 Application for Amends to Licenses DPR-62 & DPR-71,revising P-T Limits Curves Currently Located in Units 1 & 2 TSs & Deleting Current 8,10 & 12 Effective Full Power Yr Hydrostatic Test pressure-temp Limit Curves to Add New Ones BSEP-96-0343, Application for Amends to Licenses DPR-71 & DPR-62,changing Method of Detecting Reactivity Anomalies as Well as Editorial Changes to Bases for TS 3/4.1.21996-12-0404 December 1996 Application for Amends to Licenses DPR-71 & DPR-62,changing Method of Detecting Reactivity Anomalies as Well as Editorial Changes to Bases for TS 3/4.1.2 BSEP-96-0414, Application for Amends to Licenses DPR-71 & DPR-62,revising TSs to Format Consistent w/NUREG-1433,rev 1.Vols 1-15 of Improved TSs Encl1996-11-0101 November 1996 Application for Amends to Licenses DPR-71 & DPR-62,revising TSs to Format Consistent w/NUREG-1433,rev 1.Vols 1-15 of Improved TSs Encl BSEP-96-0406, Application for Amends to Licenses DPR-62 & DPR-71,allowing Full Implementation of BWROG Enhanced Option 1-A Reactor Stability Long Term Solution,Per GL 94-021996-11-0101 November 1996 Application for Amends to Licenses DPR-62 & DPR-71,allowing Full Implementation of BWROG Enhanced Option 1-A Reactor Stability Long Term Solution,Per GL 94-02 BSEP-96-0390, Application for Amend to License DPR-71,revising Minimum Critical Power Ratio Safety Limit Ref in TS 2.1.2 from 1.07 to 1.10 for Unit 1 Cycle 11 Operation & Revises TS 5.3.1 to Reflect New Fuel Type Being Added to Unit 1 Reactor Core1996-10-16016 October 1996 Application for Amend to License DPR-71,revising Minimum Critical Power Ratio Safety Limit Ref in TS 2.1.2 from 1.07 to 1.10 for Unit 1 Cycle 11 Operation & Revises TS 5.3.1 to Reflect New Fuel Type Being Added to Unit 1 Reactor Core BSEP-96-0271, Suppl to Application for Amend to License DPR-71,revising MCPR Safety Limit Specified in TS 2.1.2 from 1.07 to 1.09 for Unit 1 Cycle 11 Operation & TS 5.3.1 to Reflect New Fuel Type GE131996-07-30030 July 1996 Suppl to Application for Amend to License DPR-71,revising MCPR Safety Limit Specified in TS 2.1.2 from 1.07 to 1.09 for Unit 1 Cycle 11 Operation & TS 5.3.1 to Reflect New Fuel Type GE13 BSEP-96-0061, Application for Amend to License DPR-71,revising MCPR Safety Limits in TS 2.1.2 from 1.07 to 1.09 for Cycle 11 Operation & Revising TS 5.3.1 to Reflect New Fuel Type GE13 That Will Be Used During Refueling Outage 101996-04-0808 April 1996 Application for Amend to License DPR-71,revising MCPR Safety Limits in TS 2.1.2 from 1.07 to 1.09 for Cycle 11 Operation & Revising TS 5.3.1 to Reflect New Fuel Type GE13 That Will Be Used During Refueling Outage 10 BSEP-96-0126, Application for Amends to Licenses DPR-62 & DPR-71, Respectively,Revising TS 3.0 & 4.0 & Bases Re Applicability & Srs,Per Guidance in GL 87-09 & NUREG-14331996-04-0404 April 1996 Application for Amends to Licenses DPR-62 & DPR-71, Respectively,Revising TS 3.0 & 4.0 & Bases Re Applicability & Srs,Per Guidance in GL 87-09 & NUREG-1433 BSEP-96-0123, Application for Amends to Licenses DPR-62 & DPR-71,revising TS to Allow Uprate of Facilities to 105% of Rated Thermal Power.Proprietary & Nonproprietary Versions of GE Power Uprate SAR for Bsep... Encl.Proprietary GE Rept Withheld1996-04-0202 April 1996 Application for Amends to Licenses DPR-62 & DPR-71,revising TS to Allow Uprate of Facilities to 105% of Rated Thermal Power.Proprietary & Nonproprietary Versions of GE Power Uprate SAR for Bsep... Encl.Proprietary GE Rept Withheld BSEP-95-0561, Application for Amends to Licenses DPR-62 & DPR-71,modifying RPS Electrical Protective Assemblies Channel Functional Test Surveillance Interval in TS SR 4.8.2.5.a,per GL 91-091995-11-15015 November 1995 Application for Amends to Licenses DPR-62 & DPR-71,modifying RPS Electrical Protective Assemblies Channel Functional Test Surveillance Interval in TS SR 4.8.2.5.a,per GL 91-09 BSEP-95-0383, Application for Amends to Licenses DPR-71 & DPR-62,revising Action B of TS 3.4.4 to Allow for Chemical Decontamination of RCS During Refueling Outages1995-10-23023 October 1995 Application for Amends to Licenses DPR-71 & DPR-62,revising Action B of TS 3.4.4 to Allow for Chemical Decontamination of RCS During Refueling Outages BSEP-95-0316, Application for Amends to Licenses DPR-62 & DPR-71,proposing Changes to TS 3/4.6.1.2 & 3/4.6.1.3,by Removing Detailed Requirements Describing Type B & C Testing for PCIV & Penetrations1995-09-13013 September 1995 Application for Amends to Licenses DPR-62 & DPR-71,proposing Changes to TS 3/4.6.1.2 & 3/4.6.1.3,by Removing Detailed Requirements Describing Type B & C Testing for PCIV & Penetrations BSEP-95-0299, Requests Rev to Ts,Revising MCPR Limit,Ts 5.3.1 to Reflect New Fuel Type & Acceptable Range of Na Pentaborate Concentration for Standby Liquid Control Sys Shown in TS Figure 3.1.5-1 That Reflects Changes to Poison Matl1995-08-0404 August 1995 Requests Rev to Ts,Revising MCPR Limit,Ts 5.3.1 to Reflect New Fuel Type & Acceptable Range of Na Pentaborate Concentration for Standby Liquid Control Sys Shown in TS Figure 3.1.5-1 That Reflects Changes to Poison Matl BSEP-95-0153, Application for Amends to Licenses DPR-71 & DPR-62,adding Exemption from Requirements of TS 3.0.4 to Spec 3/4.8.1.11995-03-31031 March 1995 Application for Amends to Licenses DPR-71 & DPR-62,adding Exemption from Requirements of TS 3.0.4 to Spec 3/4.8.1.1 BSEP-95-0539, Application for Amend to Licenses DPR-71 & DPR-62,providing Clarification to Basis for Deletion of Instrumentation Surveillances from TS 3/4.6.2 on Suppression Chamber1995-02-14014 February 1995 Application for Amend to Licenses DPR-71 & DPR-62,providing Clarification to Basis for Deletion of Instrumentation Surveillances from TS 3/4.6.2 on Suppression Chamber BSEP-94-0469, Application for Amends to Licenses DPR-62 & DPR-71,removing Specific Instrumentation Requirements for Suppression Chamber Water Temp Monitoring from TS 3/4.6.2,on Suppression Chamber1994-11-16016 November 1994 Application for Amends to Licenses DPR-62 & DPR-71,removing Specific Instrumentation Requirements for Suppression Chamber Water Temp Monitoring from TS 3/4.6.2,on Suppression Chamber BSEP-94-0401, Application for Amends to Licenses DPR-62 & DPR-71,revising TS 3/4.6.1.2 by Adopting Wording for Primary Containment Integrated Leak Rate Testing Consistent W/Requirements of BWR-4 Improved STS (NUREG-1433)1994-11-16016 November 1994 Application for Amends to Licenses DPR-62 & DPR-71,revising TS 3/4.6.1.2 by Adopting Wording for Primary Containment Integrated Leak Rate Testing Consistent W/Requirements of BWR-4 Improved STS (NUREG-1433) BSEP-94-0413, Application for Amends to Licenses DPR-62 & DPR-71,proposing Ts,Increasing Instrument Surveillance Test Intervals & Allowable out-of-service Times1994-10-28028 October 1994 Application for Amends to Licenses DPR-62 & DPR-71,proposing Ts,Increasing Instrument Surveillance Test Intervals & Allowable out-of-service Times BSEP-94-0386, Application for Amends to Licenses DPR-71 & DPR-62,deleting Remaining Ets,Including Section 2/3.3.1,water Level in Discharge Canal & Section 2/3.4,meteorology1994-10-25025 October 1994 Application for Amends to Licenses DPR-71 & DPR-62,deleting Remaining Ets,Including Section 2/3.3.1,water Level in Discharge Canal & Section 2/3.4,meteorology 1999-09-28 Category:TEXT-LICENSE APPLICATIONS & PERMITS MONTHYEARBSEP-99-0126, Application for Amend to License DPR-71,revising TS 2.1.1.2 to Remove Note That Limits Use of MCPR Safety Limit Values to Cycle 12 Operation1999-09-28028 September 1999
[Table view]Application for Amend to License DPR-71,revising TS 2.1.1.2 to Remove Note That Limits Use of MCPR Safety Limit Values to Cycle 12 Operation BSEP-98-0190, Application for Amends to Licenses DPR-62 & DPR-71,deleting Various License Conditions,Making Editorial Changes & Providing Clarifying Info1998-10-27027 October 1998 Application for Amends to Licenses DPR-62 & DPR-71,deleting Various License Conditions,Making Editorial Changes & Providing Clarifying Info BSEP-98-0165, Application for Amends to Licenses DPR-62 & DPR-71,revising TS 5.2.2.f to Require Operations Manager or Assistant Operations Manager to Hold SRO License1998-08-17017 August 1998 Application for Amends to Licenses DPR-62 & DPR-71,revising TS 5.2.2.f to Require Operations Manager or Assistant Operations Manager to Hold SRO License BSEP-98-0095, Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-14331998-04-24024 April 1998 Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433 BSEP-98-0037, Application for Amends to Licenses DPR-62 & DPR-72,revising Basis for Removing Suppression Chamber Temp Water Temp Monitoring Instrumentation Requirements1998-04-0909 April 1998 Application for Amends to Licenses DPR-62 & DPR-72,revising Basis for Removing Suppression Chamber Temp Water Temp Monitoring Instrumentation Requirements BSEP-98-0049, Application for Amends to Licenses DPR-71 & DPR-82 to Modify TS 3.5.3.1 & Associated Bases Section 3/4.5.3.1,revising Specified Total Volume of Condensate Storage Tank from 150,000 Gallons to 228,200 Gallons1998-04-0303 April 1998 Application for Amends to Licenses DPR-71 & DPR-82 to Modify TS 3.5.3.1 & Associated Bases Section 3/4.5.3.1,revising Specified Total Volume of Condensate Storage Tank from 150,000 Gallons to 228,200 Gallons BSEP-98-0062, Suppl to Application for Amend to DPR-71,revising Safety Limit Min Critical Power Ratio Ref in TS 2.1.2 from 1.10 to 1.09 for Two Recirculation Loop Operation & to 1.10 for Single Recirculation Loop Operation for Fuel Cycle 121998-03-27027 March 1998 Suppl to Application for Amend to DPR-71,revising Safety Limit Min Critical Power Ratio Ref in TS 2.1.2 from 1.10 to 1.09 for Two Recirculation Loop Operation & to 1.10 for Single Recirculation Loop Operation for Fuel Cycle 12 BSEP-98-0056, Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved TS as Contained in Rev 1 of NUREG-14331998-03-13013 March 1998 Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved TS as Contained in Rev 1 of NUREG-1433 BSEP-98-0036, Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-14331998-02-26026 February 1998 Suppl Application for Amends to Licenses DPR-62 & DPR-71, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433 BSEP-98-0034, Application for Amend to License DPR-71,revising SLMCPR Referenced in TS 2.1.2 from 1.10 to 1.09 & Deleting Document Referencd in TS 6.9.3.2.c.Proprietary & non-proprietary GE Info,Encl.Proprietary Info Withheld1998-02-23023 February 1998 Application for Amend to License DPR-71,revising SLMCPR Referenced in TS 2.1.2 from 1.10 to 1.09 & Deleting Document Referencd in TS 6.9.3.2.c.Proprietary & non-proprietary GE Info,Encl.Proprietary Info Withheld BSEP-97-0506, Suppls to 961101 Application for Amend to TS to Allow Full Implementation of BWROG Enhanced Option I-A Reactor Stability long-term Solution.Suppl Expands Note in LCO 3.3.1.1,Table 3.3.1-11997-12-18018 December 1997 Suppls to 961101 Application for Amend to TS to Allow Full Implementation of BWROG Enhanced Option I-A Reactor Stability long-term Solution.Suppl Expands Note in LCO 3.3.1.1,Table 3.3.1-1 BSEP-97-0454, Application for Amends to Licenses DPR-71 & DPR-62,revising Design Basis Qualification Requirements for CREVS & CREVS Instrumentation,For Limited Period of Time1997-11-0606 November 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Design Basis Qualification Requirements for CREVS & CREVS Instrumentation,For Limited Period of Time BSEP-97-0475, Application for Amends to Licenses DPR-71 & DPR-62,adding Footnote to Surveillance Requirement (SR) 4.8.1.1.2.d to Allow Performance of SR 4.8.1.1.2.d.1,SR 4.8.1.1.2.d.4 & SR 4.8.1.1.2.d.5 in Operational Condition 1 Through 51997-11-0606 November 1997 Application for Amends to Licenses DPR-71 & DPR-62,adding Footnote to Surveillance Requirement (SR) 4.8.1.1.2.d to Allow Performance of SR 4.8.1.1.2.d.1,SR 4.8.1.1.2.d.4 & SR 4.8.1.1.2.d.5 in Operational Condition 1 Through 5 BSEP-97-0397, Application for Amends to Licenses DPR-71 & DPR-62,revising Proposed Terms in TSs 4.0.1 & 4.0.3 to Reflect Existing TS Terminology,Per GL 87-091997-11-0404 November 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Proposed Terms in TSs 4.0.1 & 4.0.3 to Reflect Existing TS Terminology,Per GL 87-09 BSEP-97-0458, Application for Amends to Licenses DPR-71 & DPR-62,revising Description of Control Rod Assemblies,Per Description Contained in NUREG-1433,Rev 11997-10-29029 October 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Description of Control Rod Assemblies,Per Description Contained in NUREG-1433,Rev 1 BSEP-97-0445, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising SRs to Remove Allowable Humidity & Temperature Testing Ranges for Charcoal Adsorber1997-10-28028 October 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising SRs to Remove Allowable Humidity & Temperature Testing Ranges for Charcoal Adsorber BSEP-97-0419, Application for Amends to Licenses DPR-71 & DPR-62,revising Certain Instrumentation Allowable Values,Per NUREG-1433,Rev 11997-10-28028 October 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Certain Instrumentation Allowable Values,Per NUREG-1433,Rev 1 BSEP-97-0443, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433.Rev a to Improved TS & Revised Responses to 970808 & 970911 RAIs Also Encl1997-10-13013 October 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Converting Current TS to Improved Ts,As Contained in Rev 1 of NUREG-1433.Rev a to Improved TS & Revised Responses to 970808 & 970911 RAIs Also Encl BSEP-97-0359, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Labels for Coordinates of TS Figures 3.4.6.1-1, 3.4.6.1-2,3.4.6.1-3a & 3.4.6.1-3b as Pressure (Psig) & Temp (F)1997-08-27027 August 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Labels for Coordinates of TS Figures 3.4.6.1-1, 3.4.6.1-2,3.4.6.1-3a & 3.4.6.1-3b as Pressure (Psig) & Temp (F) BSEP-97-0319, Application for Amends to Licenses DPR-62 & DPR-71,approving Method of Transferring Spent Fuel Shipping Cask1997-08-0606 August 1997 Application for Amends to Licenses DPR-62 & DPR-71,approving Method of Transferring Spent Fuel Shipping Cask BSEP-97-0277, Application for Amends to Licenses DPR-62 & DPR-71, Clarifying TS 4.0.5.f Re Use of NRC Staff Approved Alternatives to Recommendations of GL 88-01, NRC Staff Position of IGSCC in BWR Austenitic Stainless Steel Piping1997-07-25025 July 1997 Application for Amends to Licenses DPR-62 & DPR-71, Clarifying TS 4.0.5.f Re Use of NRC Staff Approved Alternatives to Recommendations of GL 88-01, NRC Staff Position of IGSCC in BWR Austenitic Stainless Steel Piping BSEP-97-0315, Application for Amends to Licenses DPR-62 & DPR-71,revising Tech Specs 5.2.2.b & 5.4.2 Re Containment & RCS Design Features1997-07-18018 July 1997 Application for Amends to Licenses DPR-62 & DPR-71,revising Tech Specs 5.2.2.b & 5.4.2 Re Containment & RCS Design Features BSEP-96-0337, Application for Amends to Licenses DPR-62 & DPR-71,updating TS 3.6.1.6 to Support Upgrade to Containment Average Air Temp Limit Associated W/Conversion to Improved Tss.Encl Proprietary Rept & TSs Withheld1997-06-12012 June 1997 Application for Amends to Licenses DPR-62 & DPR-71,updating TS 3.6.1.6 to Support Upgrade to Containment Average Air Temp Limit Associated W/Conversion to Improved Tss.Encl Proprietary Rept & TSs Withheld BSEP-97-0222, Application for Amends to Licenses DPR-71 & DPR-62,revising Action Statements a.1 & a.2 of TS 3/4.4.5 by Reducing Max Allowed Reactor Coolant Specific to Activity1997-05-23023 May 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Action Statements a.1 & a.2 of TS 3/4.4.5 by Reducing Max Allowed Reactor Coolant Specific to Activity BSEP-97-0168, Application for Amends to Licenses DPR-71 & DPR-62,revising Surveillance Requirements to Require Testing of Control Room Emergency Ventilation Sys Charcoal & Revising Acceptance Criteria for Subject Charcoal Testing1997-04-30030 April 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Surveillance Requirements to Require Testing of Control Room Emergency Ventilation Sys Charcoal & Revising Acceptance Criteria for Subject Charcoal Testing BSEP-97-0144, Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Tech Specs 3.0 & 4.0 & Respective Bases for Sections to Incorporate Guidance Contained in NRC GL 87-091997-04-14014 April 1997 Suppl to Application for Amends to Licenses DPR-71 & DPR-62, Revising Tech Specs 3.0 & 4.0 & Respective Bases for Sections to Incorporate Guidance Contained in NRC GL 87-09 BSEP-97-0135, Application for Amends to Licenses DPR-71 & DPR-62,revising Requirements for Instrumentation Response Time Testing Associated W/Rps,Isolation Actuation Sys & ECCS1997-04-11011 April 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Requirements for Instrumentation Response Time Testing Associated W/Rps,Isolation Actuation Sys & ECCS BSEP-97-0125, Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time1997-03-27027 March 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time BSEP-97-0120, Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time1997-03-24024 March 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Definitions for ECCS Response Time,Isolation Sys Response Time & Reactor Protection Sys Response Time BSEP-97-0012, Application for Amends to Licenses DPR-71 & DPR-62 to Incorporate New TS Which Applies to Condenser Vacuum Pump Isolation Instrumentation1997-03-0505 March 1997 Application for Amends to Licenses DPR-71 & DPR-62 to Incorporate New TS Which Applies to Condenser Vacuum Pump Isolation Instrumentation BSEP-96-0447, Application for Amends to Licenses DPR-71 & DPR-62,revising Minimum & Maximum Values of Pressure Suppression Pool Water Vols Contained in TS 3.6.2.1.a.1 & Corresponding Bases1997-01-15015 January 1997 Application for Amends to Licenses DPR-71 & DPR-62,revising Minimum & Maximum Values of Pressure Suppression Pool Water Vols Contained in TS 3.6.2.1.a.1 & Corresponding Bases BSEP-96-0344, Application for Amends to Licenses DPR-62 & DPR-71,revising P-T Limits Curves Currently Located in Units 1 & 2 TSs & Deleting Current 8,10 & 12 Effective Full Power Yr Hydrostatic Test pressure-temp Limit Curves to Add New Ones1997-01-0707 January 1997 Application for Amends to Licenses DPR-62 & DPR-71,revising P-T Limits Curves Currently Located in Units 1 & 2 TSs & Deleting Current 8,10 & 12 Effective Full Power Yr Hydrostatic Test pressure-temp Limit Curves to Add New Ones BSEP-96-0343, Application for Amends to Licenses DPR-71 & DPR-62,changing Method of Detecting Reactivity Anomalies as Well as Editorial Changes to Bases for TS 3/4.1.21996-12-0404 December 1996 Application for Amends to Licenses DPR-71 & DPR-62,changing Method of Detecting Reactivity Anomalies as Well as Editorial Changes to Bases for TS 3/4.1.2 BSEP-96-0414, Application for Amends to Licenses DPR-71 & DPR-62,revising TSs to Format Consistent w/NUREG-1433,rev 1.Vols 1-15 of Improved TSs Encl1996-11-0101 November 1996 Application for Amends to Licenses DPR-71 & DPR-62,revising TSs to Format Consistent w/NUREG-1433,rev 1.Vols 1-15 of Improved TSs Encl BSEP-96-0406, Application for Amends to Licenses DPR-62 & DPR-71,allowing Full Implementation of BWROG Enhanced Option 1-A Reactor Stability Long Term Solution,Per GL 94-021996-11-0101 November 1996 Application for Amends to Licenses DPR-62 & DPR-71,allowing Full Implementation of BWROG Enhanced Option 1-A Reactor Stability Long Term Solution,Per GL 94-02 BSEP-96-0390, Application for Amend to License DPR-71,revising Minimum Critical Power Ratio Safety Limit Ref in TS 2.1.2 from 1.07 to 1.10 for Unit 1 Cycle 11 Operation & Revises TS 5.3.1 to Reflect New Fuel Type Being Added to Unit 1 Reactor Core1996-10-16016 October 1996 Application for Amend to License DPR-71,revising Minimum Critical Power Ratio Safety Limit Ref in TS 2.1.2 from 1.07 to 1.10 for Unit 1 Cycle 11 Operation & Revises TS 5.3.1 to Reflect New Fuel Type Being Added to Unit 1 Reactor Core BSEP-96-0271, Suppl to Application for Amend to License DPR-71,revising MCPR Safety Limit Specified in TS 2.1.2 from 1.07 to 1.09 for Unit 1 Cycle 11 Operation & TS 5.3.1 to Reflect New Fuel Type GE131996-07-30030 July 1996 Suppl to Application for Amend to License DPR-71,revising MCPR Safety Limit Specified in TS 2.1.2 from 1.07 to 1.09 for Unit 1 Cycle 11 Operation & TS 5.3.1 to Reflect New Fuel Type GE13 BSEP-96-0061, Application for Amend to License DPR-71,revising MCPR Safety Limits in TS 2.1.2 from 1.07 to 1.09 for Cycle 11 Operation & Revising TS 5.3.1 to Reflect New Fuel Type GE13 That Will Be Used During Refueling Outage 101996-04-0808 April 1996 Application for Amend to License DPR-71,revising MCPR Safety Limits in TS 2.1.2 from 1.07 to 1.09 for Cycle 11 Operation & Revising TS 5.3.1 to Reflect New Fuel Type GE13 That Will Be Used During Refueling Outage 10 BSEP-96-0126, Application for Amends to Licenses DPR-62 & DPR-71, Respectively,Revising TS 3.0 & 4.0 & Bases Re Applicability & Srs,Per Guidance in GL 87-09 & NUREG-14331996-04-0404 April 1996 Application for Amends to Licenses DPR-62 & DPR-71, Respectively,Revising TS 3.0 & 4.0 & Bases Re Applicability & Srs,Per Guidance in GL 87-09 & NUREG-1433 BSEP-96-0123, Application for Amends to Licenses DPR-62 & DPR-71,revising TS to Allow Uprate of Facilities to 105% of Rated Thermal Power.Proprietary & Nonproprietary Versions of GE Power Uprate SAR for Bsep... Encl.Proprietary GE Rept Withheld1996-04-0202 April 1996 Application for Amends to Licenses DPR-62 & DPR-71,revising TS to Allow Uprate of Facilities to 105% of Rated Thermal Power.Proprietary & Nonproprietary Versions of GE Power Uprate SAR for Bsep... Encl.Proprietary GE Rept Withheld BSEP-95-0561, Application for Amends to Licenses DPR-62 & DPR-71,modifying RPS Electrical Protective Assemblies Channel Functional Test Surveillance Interval in TS SR 4.8.2.5.a,per GL 91-091995-11-15015 November 1995 Application for Amends to Licenses DPR-62 & DPR-71,modifying RPS Electrical Protective Assemblies Channel Functional Test Surveillance Interval in TS SR 4.8.2.5.a,per GL 91-09 BSEP-95-0383, Application for Amends to Licenses DPR-71 & DPR-62,revising Action B of TS 3.4.4 to Allow for Chemical Decontamination of RCS During Refueling Outages1995-10-23023 October 1995 Application for Amends to Licenses DPR-71 & DPR-62,revising Action B of TS 3.4.4 to Allow for Chemical Decontamination of RCS During Refueling Outages BSEP-95-0316, Application for Amends to Licenses DPR-62 & DPR-71,proposing Changes to TS 3/4.6.1.2 & 3/4.6.1.3,by Removing Detailed Requirements Describing Type B & C Testing for PCIV & Penetrations1995-09-13013 September 1995 Application for Amends to Licenses DPR-62 & DPR-71,proposing Changes to TS 3/4.6.1.2 & 3/4.6.1.3,by Removing Detailed Requirements Describing Type B & C Testing for PCIV & Penetrations BSEP-95-0299, Requests Rev to Ts,Revising MCPR Limit,Ts 5.3.1 to Reflect New Fuel Type & Acceptable Range of Na Pentaborate Concentration for Standby Liquid Control Sys Shown in TS Figure 3.1.5-1 That Reflects Changes to Poison Matl1995-08-0404 August 1995 Requests Rev to Ts,Revising MCPR Limit,Ts 5.3.1 to Reflect New Fuel Type & Acceptable Range of Na Pentaborate Concentration for Standby Liquid Control Sys Shown in TS Figure 3.1.5-1 That Reflects Changes to Poison Matl BSEP-95-0153, Application for Amends to Licenses DPR-71 & DPR-62,adding Exemption from Requirements of TS 3.0.4 to Spec 3/4.8.1.11995-03-31031 March 1995 Application for Amends to Licenses DPR-71 & DPR-62,adding Exemption from Requirements of TS 3.0.4 to Spec 3/4.8.1.1 BSEP-95-0539, Application for Amend to Licenses DPR-71 & DPR-62,providing Clarification to Basis for Deletion of Instrumentation Surveillances from TS 3/4.6.2 on Suppression Chamber1995-02-14014 February 1995 Application for Amend to Licenses DPR-71 & DPR-62,providing Clarification to Basis for Deletion of Instrumentation Surveillances from TS 3/4.6.2 on Suppression Chamber BSEP-94-0401, Application for Amends to Licenses DPR-62 & DPR-71,revising TS 3/4.6.1.2 by Adopting Wording for Primary Containment Integrated Leak Rate Testing Consistent W/Requirements of BWR-4 Improved STS (NUREG-1433)1994-11-16016 November 1994 Application for Amends to Licenses DPR-62 & DPR-71,revising TS 3/4.6.1.2 by Adopting Wording for Primary Containment Integrated Leak Rate Testing Consistent W/Requirements of BWR-4 Improved STS (NUREG-1433) BSEP-94-0469, Application for Amends to Licenses DPR-62 & DPR-71,removing Specific Instrumentation Requirements for Suppression Chamber Water Temp Monitoring from TS 3/4.6.2,on Suppression Chamber1994-11-16016 November 1994 Application for Amends to Licenses DPR-62 & DPR-71,removing Specific Instrumentation Requirements for Suppression Chamber Water Temp Monitoring from TS 3/4.6.2,on Suppression Chamber BSEP-94-0413, Application for Amends to Licenses DPR-62 & DPR-71,proposing Ts,Increasing Instrument Surveillance Test Intervals & Allowable out-of-service Times1994-10-28028 October 1994 Application for Amends to Licenses DPR-62 & DPR-71,proposing Ts,Increasing Instrument Surveillance Test Intervals & Allowable out-of-service Times BSEP-94-0386, Application for Amends to Licenses DPR-71 & DPR-62,deleting Remaining Ets,Including Section 2/3.3.1,water Level in Discharge Canal & Section 2/3.4,meteorology1994-10-25025 October 1994 Application for Amends to Licenses DPR-71 & DPR-62,deleting Remaining Ets,Including Section 2/3.3.1,water Level in Discharge Canal & Section 2/3.4,meteorology 1999-09-28 |
Text
,
4&L Carolina Power & Light Company File: NG -3514 (B) May 27, 1980 SERIAL: NO-80-783 Office of Nuclear Reactor Regulation Attention: Mr. T. A. Ippolito, Chief Operating Reactors Branch No. 3 United States Nuclear Regulatory Commission Washington, D. C. 20555 BRUNSWICK STEAM ELECTRIC PLANT UNIT NO. 2 DOCKET No. 50-324 LICENSE NO. DPR-62 REQUEST FOR LICENSE AMENDMENT - HYDRAULIC SNUBBER DELETION
Dear Mr. Ippolito:
In accordance with the Code of Federal Regulations, Title 10, Part 50.90 and Part 2.101, Carolina Power & Light Company (CP&L) hereby requests revisions to the Technical Specifications for its Brunswick Steam Electric Plant (BSEP) Unit No. 2. The requested revision deletes four hydraulic snubbers from the list of Table 3.7.5-1 in the Technical Specifications.
The Brunswick Plant is currently implementing plant modifica-tions to the Unit 2 reactor vessel instrumentation. Analyses performed in conjunction with this modification have disclosed that four hydraulic snubbers are not necessary. These snubbers are being replaced with rigid supports. The presence of rigid supports will enhance the reli-ability of the system, and does not compromise the ability of the reactor vessel instrumentation system to perform its function since che analysis shows that all stresses remain below the FSAR defined limits.
A revised page for Table 3.7.5-1 is attached with changes indicated by a vertical bar in the right hand margin. In ac-crdance with 10CFR170.12(c), we have determined that this revision constitutes a Class III amendment. Accordingly, our check for $4000 is enclosed as payment for this amendment fee.
411 Fayetteville Street
- P. O. Box 1551 e Raleigh, N C. 27602 iO:- mm q_ =- --<s.m.
= _ s rm e m e .- m u-o ,i 800gggg Y&
This modification is currently being made to Brunswick Unit 2 during its refueling outage, and we plan to start the unit up in early June, 1980. Therefore, we request that you review and approve this request on an expedited basis for inclusion in the BSEP-2 refueling license amendment.
If you have any questions on this request, please contact my Staff. Your Cooperation is appfcClated.
Yours very truly, g }. m o _ -
" tr h E. E. Utley Executive Vice President Power Supply and Engineering & Construction Sworn to and subscribed before me this 27th day of May, 1980.
$ $24A&2thJ ,
My commission expires: 10/4/81 CSB/je (7215) '
Attachment ssen n.. j WM .
^
.: s
- 2. u i
!s h,sOTARY AU B LIO .I 0
... .. . s . l I
1 l
1 l
l l
l l