ML19312E130

From kanterella
Jump to navigation Jump to search
Forwards Design Review of Plant Shielding & Environ Qualification of Equipment for Spaces/Sys Which May Be Used in Post-Accident Operations Outside Containment at Crystal River Unit 3 Nuclear Generating Station, Revision 1
ML19312E130
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 06/01/1980
From: Richard Bright
FLORIDA POWER CORP.
To: Reid R
Office of Nuclear Reactor Regulation
Shared Package
ML19312E131 List:
References
RTR-NUREG-0578, RTR-NUREG-578 3--3-2-3, 3-0-3-2-3, NUDOCS 8006030323
Download: ML19312E130 (2)


Text

a h8b 31

[3NhM.iiss J

aug%s'2p

"#4jsf Florida Power Co m PO M A Y so re June 1, 1980 File:

3-0-3-a-3 Mr. Robert W. Reid Chief Operating Reactor Branch #4 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 NUREG-0578 Section 2.1.6.b -

Shield Review Report Revision 1

Reference:

FPC letter, dated January 11, 1980 to Mr. Harold R. Denton from P. Y. Baynard

Dear Mr. Reid:

This submittal is in response to Item 2.1.6.b of NUREG-0578, identified in your letter of May 5,1980, concerning the staff's evaluation of the imple-mentation of Category "A" Lessons Learned requirement at Crystal River Unit 3.

Florida Power Corporation has completed the review which determined the needed modifications to provide access to vital areas and to protect vital mechanical equipment.

The attached report presents the results of the re-view and supersedes Attachment III of the referenced letter.

Should you have any questions concerning this subject, please contact this office.

Sincerely, FLORIDA POWER CORPORATION Y1 R. M. Bright' i

Acting Manager Nuclear Support Services RMBemhF0906

'8006080323 l

General Office 3201 Thirty-rourtn street soutn. P O Box 14042. st Petersburg. Fionda 33733 e 813-866-5151

Y e$.

  • h STATE OF FLORIDA COUNTY OF PINELLAS R.

M.

Bright states that he is the Acting Manager, Nuclear Support Services Department of Florida Power Corporation; that he is authorized on the part of said company to sign and file with the Nuclear Regulatory Comission the information attached hereto; and that all such statements made and matters set forth therein are true and correct to the best of his knowledge, information and belief.

R.

M'. Bri ght Subscribed and sworn to before me, a Notary Public in and for the State and County above named, khis 1st day of June,1980.

4"

~.w Notary Public Notary Public, State of Florida at Large, My Commission Expires: August 24, 1983