March 17,- 1980 File: -NG-3514(B)
SERIAL NO: NO-80-422 Office'of Nuclear Reactor Regulation Attention:
Mr. D. G. Eisenhut, Acting Director Division of Operating Reactors United States Nuclear Regulatory Commission
-Washington, D. C.
20555 Brunswick Steam Electric Plant, Unit Nos. 1 and 2 Docket Nos. 50-325 and 50-324 License Nos. DPR-71 and DPR-62 LWR Primary Coolant System Pressure Isolation Valves
Dear Mr. Eisenhut:
This letter is in response to your February 23, 1980 letter which requested information to describe isolation valve configuration and to indicate if an Event V isolation valve configuration exists within the Class I boundary of the high pressure piping connecting Primary Coolant System (PCS) piping to low pressure system piping.
Carolina Power & Light Company (CP&L) submits the following information for the Brunswick Steam Electric Plant (BSEP) Unit Nos. 1 and 2.
.Only two systems at BSEP, Residual Heat Removal (RHR) and Core Spray
'(CS), meet the criteria of a system where PCS piping and low pressure piping both exist on the same system..The valve configuration on both of these systems at BSEP~ consists of.a. check valve with two motor-operated valves in series. This is not one of the valve configurations of concern addressed in your letter. These motor-operated valves are Type "C hak rate tested at each refueling outage per 10CFR50, Appendix J.
We cr*-. that this information satisfies your request for Event V isolation v
..s information.
g/
Yours very truly, A/5 GA S. E. Utley y'pDl 5 b / 0 Executive Vice President-f. Power Supply & Customer Services 6,39)c/E{ 7 g '.RMP/CSB/tl-Sworn to and subscribed before me this 17th day of March 1980 $p__ 1 OkM.m m > 1 f Notary Pub g 8 V / t j }goTARy'g g -My Commission Expires: October 4, 1981 cc: 1Mr.-.T. A.' Ippolito kI E ! f h 5 g f-80osa o 5,~18 '"'*" -.}}