Ro:On 761222,quantity of Gaseous Radioactive Waste Released During Fourth Quarter Exceeded Annual Objective.Caused by Leaks in RCS Valves from Pressurizer Gas Space to Reactor Bldg Atmosphere.Leaks Repaired
ML19312C453
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 01/20/1977
From: Parker W
DUKE POWER CO.
To:
References
NUDOCS 7912130979
Download: ML19312C453 (1)


Text

DUKE power COMPANY P, _,9 n p4 Powra Butt.ntwo 422 SocTa Cucacu STartT. Cn.ARI.OTTE, F C. 28242 k( '

.p -

.. w i

o. =4.=ca.sa.

January 20, 1977

/ict Pettact=T TE AEP=C%c As ta 70 4 Svea.e Peoowetio=

2'3 40S1 Mr. Norman C. Moseley, Director U. S. Nuclear Regulatory Commission Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 Re: Oconee Nuclear Station Docket Nos. 50-269, -270, -287

Dear Mr. Moseley:

Pursuant to the requirements of Oconee Nuclear Station Technical Specifi-cation 3.10.1, this report is submitted describing a condition in which the rate of release of radioactive materials in gaseous wastes averaged over a calendar quarter would have exceeded twice the annual objective if the same release rate had been maintained over a one year period.

On December 22, 1976, the quantity of gaseous radioactive waste released from Oconee Nuclear Station during the fourth quarter reached 25,600 curies.

If this same release rate were maintained over a year, Oconee Nuclear Station would have exceeded twice its annual objective of 51,000 curies of released radioactive gaseous waste.

This condition resulted from the necessity of purging the Oconee Unit 2 Reactor Building to allow personnel entry for steam generator tube repair.

The purge added approximately 12,600 curies of released gaseous waste to the quarterly total. The activity in the Unit 2 Reactor Building has been considerably higher than normal. The major contributor of this activity has been leaks in reactor coolant valves from the pressurizer gas space to the Reactor Building atmosphere. These leaks have been repaired and this should alleviate this situation in the future.

Although a large quantity of gaseous waste was released during the fourth quarter, the amount of released radioactive gaseous waste during the calen-dar year did not exceed the station's annual objective of 51,000 curies.

Also, restrictions were placed on other purging operations to assure that no limitations for gaseous release rates were exceeded. Therefore, it is concluded that the health and safety of the public were not adversely affected by this condition.

Very truly yours,

/

William O. Parker, Jr.

0 LJB:ge ygig13