Text

-.

i

('

0' Superintendent I*'

Clerical Staff Asst. Supt.

,g I

/

Operating SRO Technical Support Maintenance Engineer Engineer Engineer d

f M

i Maintenance z

A.'s t. Operating H

m Supervisor 1

e s.,gineer SRO I

Performance Instrument Chemistry-Health l

Engineer Supervisor Physics Supv.

1 Asst. Maintenance Shift SRO Supervisor i

Supervisor

'I Instrument Chemistry-Health g

p Physics Personnel Personnel ye Control RO Maintenance SRO - Senior Reactor Operator License Personnel g

Operator e4 RO - Reactor Operator License g

Asst. Control i

Operator RO OCONEE NUCLEAR STATION STATION ORGANIZATION CHART Utility Operator FIGURE 6.1-1 m

m

ATTACllMENT 3 b.

At least one licensed Reactor Operator per unit and two Senior Reactor Operators shall be at the station at all times when there is fuel in two reactor vessels.

One licensed operator per unit shall be in the control room for that unit. At no time will the shift crew be less than three persons per unit.

Two licensed reactor operators shall be in the control room during c.

startup and scheduled shutdown of the reactor, and during recovery from reactor trips.

d.

At least one licensed reactor operator shall be in the reactor building when fuel handling operations are in progress in the reactor building. An operator holding a Senior Reactor Operators license and assigned no other concurrent operational duties shall be in direct charge of refueling operations, e.

At least one operator per shift for eaca unit will have sufficient training to perform routine health physics requirements.

f.

If the computer for a reactor is inoperable for more than eight (8) hours, an additional operator shall be called in to supplement i

the shift crew.

6.1.2 Review and Audit In matters of nuclear safety and radiation exposure, review and audit of station operation, maintenance and technical matters shall be pro-vided by two committees as follows (Reference Figure 6.1.2):

J 6.1.2.1 Station Review Committee a.

Membership The Superintendent shall appoint an on-site review committee consisting of at least five members of the station supervisory staff. Representation shall be provided from Operations and

]

from Technical Support.

Membership shall include expertise appropriate to the items being considered by the committee.

The chairman of the on-site review committee shall be appointed by the Superintendent.

b.

Meeting Frequency l

This committee shall meet at least once each month and as J

required on call by the chairman.

{

l i

c.

Quorum The chairman plus two members shall constitute a quorum.

d.

Responsibilities q

The committee shall have the following responsibilities:

d (1) Review all new procedures or proposed significant, safety-f related changes to existing procedures as determined by I

the Station Superintendent.

]

6.1-2

]

1