-:e.
- [ 'j p *"8009'o 1 UNITED STATES
~
CLEAR REGULATORY COMMISSION NU v4
y
- y 4 ',
REGION IV y
o 811 RY AN PLAZA DRIVE.SulTE 1000 er
- l.
ARLINGTON. TEXAS 76012 o'
g 0 8 MAY 1980
% ".. f.
- +
-Docket No. 99900340/80-01 Yarway Corporation Attn: Mr. S. F. Myers Corporation Vice President of Reliability Blue Bell, Pennsylvania 19422 Gentlemen:
This refers to the QA Program inspection conducted by Mr. William D. Kelley of this office on April 22-24 of your facility at Blue Bell,~ Pennsylvania, associated with the manufacture of ASME Section III "N" Class 1, 2, and 3 valves and to the discussions of our findings with Mr. W. D. Clinton and members of your staff at the conclusion of the inspection.
This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort'is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality.
As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others.
You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective cor-rective action in response to their findings.
A. teas eyamined and our findings are discussed in the enclosed report. Within these areas, the' inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
Duringtheinspecth.onitwasfoundthattheimplementation=ofyourQAProgram failed to meet certain NRC requirements.
The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.
]
'Please provide us within thirty (30) days of your receipt of this report a.
written-statement containing, (1) a l description of steps that have been or will be taken to correct these items, (2) a description of steps that have been or will be taken' to prevent recurrence, and (3) the date your corrective actions and preventive measures were or will be completed.
8007010: d3[
Yarway Corporation 2
In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the informa-tion is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, l.,
l f'
s Uldis ocapovs, Chief Vendor Inspection Branch
Enclosures:
1.
Notice of Deviation 2.
Inspection Report No. 99900340/80-01 t