LER 80-029/03L:on 800323,following Reactor Scram,Hpci Discharge Valve E41-F006 Would Not Remain Open Following Low Level Initiation Signal.Caused by HPCI Turbine Stop Valve E41-V8 Opening Too Quickly.Spring Loaded Bypass Adjusted