{{#Wiki_filter:nta%[o e ., p I/C UNITED STATES p NUCLEAR REGULATORY COMMISSION
3 y, g g c REGION lli b[ r,$, 799 ROOSEVELT ROAD e %.....o GLEN ELLYN. lLLINOIS 60137 FEB 2 6 ug Docket No. 50-440 Docket No. 50-441 The Cleveland Electric Illuminating Company ATTN: Dalwyn R. Davidson Vice President System Engineering and Construction Post Office Box 5000 Cleveland, OH 44101 Gentlemen: This refers to the inspection conducted by Messrs. J. E. Konklin and W. J. Key of this office on January 23-25, 1980, of activities at the Perry Nuclear Plant Project, Units 1 and 2, authorized by NRC Construc- tion Permits No. CPPR-148 and No. CPPR-149 and to the discussion of our findings with Messrs. G. W. Croscup and M. R. Edelman at the conclusion of the inspection. The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, obser- vations, and interviews with personnel. During this inspection, certain of your activities appeared to be in noncompliance with NRC requirements, as described in the enclosed Appendix A. This notice is sent to you pursvant to the provisions of Section 2.201 of NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regula- tions. Section 2.201 requires you to submit to this office within thirty days of your receipt of this notice a written statement or explanation in reply, including for each item of noncompliance: (1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved. t In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter, the enclosures, and your response to this letter will be placed in the NRC's 8004110 I 's o
~e. The Cleveland Electric -2- [[820 ISbt
Illuminating Company Public Document Room, except as follows. If the enclosures contain information that you or your contractors believe to be proprietary, you must apply in writing to thia office, within twenty days of your receipt of this letter, to withhold such information from public dis- , closure. The application must include a full statement of the reasons for which the informatica is considered proprietary, and should be pre- pared so that proprietary information identified in the application is contained la an enclosure to the application. We will gladly discuss any questions you have concerning this inspection. Sincerely, 48W~ G .' lorelli, Chief Reactor Construction and Engineering Support Branch Enclosures: 1. IE Inspection Rpts No. 50-440/80-01, and No. 50-441/80-01 , 2. Appendix A, Notice of Violation cc w/encls: Central Files Reproduction Unit NRC 20b PDR Local PDR NS1C TIC Harold W. Kohn, Ohio Power Siting Commission Mr. Daniel D. Wilt, Attorney Helen W. Evans, State of Ohio i . }}