ML19309A610

From kanterella
Jump to navigation Jump to search
Forwards B&W Deficiency Rept Re Possible Ejected Rod Worth Values in Excess of Tech Spec Limits Per Certain Conditions,Supplementing B&W 741227 Rept.W/O Encl
ML19309A610
Person / Time
Site: Davis Besse, Oconee, Mcguire, Arkansas Nuclear, Crystal River, Rancho Seco, McGuire, Crane  Duke Energy icon.png
Issue date: 02/23/1975
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Anthony Giambusso
Office of Nuclear Reactor Regulation
Shared Package
ML19309A611 List:
References
NUDOCS 8003310495
Download: ML19309A610 (1)


Text

_ _ - _ _ _ _ _ _

IJ FE.G 2 $

i A. Gicctusso. Dircctor. Division of Reactor Licensing, liRR EABCCCK Aria li!LCOX DF.FICIE!!CY REP' ORT Oil CALCliLATIcil 0F EdECTED RCD

!!URTHS (AITS Il10163fil)

Er. closed is the 10 CFR 50.53(c) report frca Babecck cnd Wilcox concerning possible ejected rod worth valucs in excess of technical specification limits under certain conditions. This is suppicmental to the notification ycu received free Mr. I! allay, of Babcock and Uilcox, on Decceber 27,1974.

I understand this catter is currently under ravicw for the affceted facilities (Rancho Seco. Oconc and 3. Three Nile Island 1. and Arkansas, Nuclear One 1).,

Original signed W

~

D. II. Grica d.11. Griar. Assistant Director i

for Construction and Operations i

1 Office of Inspection and Enforcement'

~

Enclosure:

As stated t'

a ee

}

g 4

s0,e

(

8003310 y{[ [

1

.