O O

I UNITED STATES p)

  • p %

ATOMIC ENERGY COMMISS:bN

(

I k WASHINGTON. D.C. 20545

\\

J tr g

-e ar AUG 101972 G. W. Reinmuth, Chief Technical Assistance Branch, RO WELD CRACKS IN RANCHO SECO STEAM GENERATOR SUPPORT STRUCTURES (LICENSEE CDR OF JULY 24,1972 - NO. 12)

The licensee's evaluation of the subject weld cracking and related corrective measures being taken to resolve the problem appear to be satisfactory. However, with reference to the field acceptance inspection program, the engineering evaluation intended relative-to the classification of defects found is not clear.

In view of the ostensive delayed-cracking inherent to welding T-1 class steels, all linear disposed defects disclosed by dye-penetrant inspection

- '" Se subject to repair-inspection considerations. Moreover,

_..r by welding is required, an equivalent acceptance inspection

..iteria, including a delay-time reference to its application, should be imposed on the affected areas to insure the desired quality.

M M

W./. Collins Metallurgical Engineer Technical Assistance Branch, RO O

8003260[

W_,.

9

-.y-,o