ML19308D146
| ML19308D146 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 07/07/1977 |
| From: | Stewart W FLORIDA POWER CORP. |
| To: | |
| Shared Package | |
| ML19308D108 | List: |
| References | |
| NUDOCS 8002270624 | |
| Download: ML19308D146 (2) | |
Text
_ _ _ _ _ _
W
=
-.m......_._
._s.....
... v...
y-CONinOL Ot.OCK;,
l l
l l
l l
(ptcASc psalNT ALL 11CoutaCU IrJs Cat.1A1:c.
1 6
if I
'N
/
A t (CtNSC Nuuutn E
175 (I'u)9lF lLlCl Rl Pl 3ll 0 l 0-l-l 0l 0l 0l 0l 0l-l 0l Oj l 4l 1l 1l 1l1l l0l1l
~75 2G.
30 31 32 14 15 P
17e[ $ Eict cAircony DECKET NUMotit tytNT DATE ACPOnt Daft E] CONT l-I- l LT_J Lt._J
!a l s 101-101310l21 l 016 l 31017 I 71
[ 0 l 710 ! 7 I 717
'/ 18 L7 LU LD 00 61 G8 09 74 73 ti EVENT O!:SCTcI'llON l3t-) l In Modo 1, reducing power to less than 607, thermal power, as required by Technical f uu il
@l Specification Action Statement 3.1.3.3.A.1, the 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> time limit was exceeded by 7 il 9 Eh hl one hour and seven minute s.
Redundancy NA.
First time occurrence.
Personnel were 7 nu er
$l instructed to take necessary steps to insure that required time limits are met.
7
- 3 u g;
O',
$$snu cAust cou"U!tur (LER 77_62) coucoucul COOL CODE COMPONENT CODE Su m (H MAra.tAClui(A vcLAloN
{Z lZ l lAj l Zl Z lZ l Z l Z l Z' ]
y l 2 l 9 l9 l9 l W
o 7 18 0 10 11 12 17 43 44 47 au CAUSE DESCIUPilON
- *8; f.
bl The event was the result of operator failure to stare power reduction in time to j
hl satisfy the allowed time frame as set forth by Technical Specifications.
j 00 61 (10
.I FAcan y METHoo OF STATUS
% POWtn OTHtn STATUS DaScovinY DISCOVERY OCSCRIPTON W
l 0l 5l 8l l
' NA l d l Review of Operators' Log l
/0 9
10 12 -13 44 45 40 CO ACTMff COflTENT f4(LEAstt3 OF 6:ttt ASE l (Z_j '
AM0uNT OF ACTMTV h
d LOCAIGN OF RCLEASC NA l
l NA l
7 U 9
10 11 44 45 PERSONNEL EXPOSunES 00 NUMOf f t TYPE DISCnPTON
[TE 1010101 l zl I
NA l
/ 09 11 12 13 60 PERSONNEL INJtif ties NUMDin DCCCHtPTON
@ l0l0 j 0l l
NA l
/ 0u 11 12 00 OFFSITE CONSEQUENCES E@ l NA 00 l
UU LOSS OR DAMAGE TO FAC! LIT,Y 1YI Ot CC84ar*iCN M l [t l
NA l
0D 10 I,0 PUBLIC11Y Bl NA
'l
- tl D i:u
)
ADOll!ONAL i ACTORS
?
See attached Sup2 cnentary In formation 1
, _,,; h jpjl 8 0 02 270 Of
,,, c nu 1
NAMt :
2.M a.P
.G C P3U1II._.. __.___.
I q tot :( - (IIl "O PP /> ;/; 1 'e9 s
O em
~-
SUPPLEMEffrARY INFORMATION J
1.
Report No.:
50-302/77-62 2.
Facility:
Crystal River Unit #3 3.
Report Date:
7 July 1977 4.
Occurrence Date:
30 June 1977 5.
Identification of Occurrence:
Exceeded the 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> time limit for reduction to less than / % thermal power as required by Technical Specification Action Statement 3.1.3.3. A.1.
6.
Conditions Prior to Occurrence:
Verifying the position of Rod 3, Group 6 as required by Technical Specification f-3.1.3.3, upon loss of the absolute position indication.
7.
Description of Occurrence:
As a result of loss of absolute position indication of Control Rod 3, Group 6, power reduction to less than 60% thermal power was required to be achieved within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> by Technical Specification Action Statement 3.1.3.3.A.1.
Be-cause of several minor difficulties af ter the initiation of power reduction, the 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> time limit was exceeded by I hour and 7 minutes. At that time (0600),
the Action Statement was met except for the time interval. Conditions surround-ing absolute position indication failure will be reported as a 30 day written report prior to 30 July 1977.
8.
Designation of Apparent Cause:
This event was a result of operator failure to anticipate the potential for equipment problems which retarded power reduction to less than 60% in the re-quired time frame.
9.
Analysis of Occurrence:
There was no safety related significance to this event.
~
10.
Corrective Action:
Operations personnel were instructed to heed Technical Specification requirements as to time frame limits more conservatively and take necessary steps to insure these time limits are met.
- L 11.
Failure D'aca:
A c
)
This event was non-repetitive.
j