D D

oo g"y y,'=

l' Vepco VIRGINI A ELECTRIC AND POWER COMP ANY, RICHMONO, VIRGINI A 23261 October 10, 1979

'2.Nws P. O'Reillv, Sir =ctor Seri21 10. N7A Office of Insoaction t Enfo-conent

> set /SC.':mac: wang

'J.

S. '!ucl?ar R?quiatory Co mission P?gion II Doc!:et 1c. TC-F

'M Marietca Street, Suite ECO Atlan+1, 1ecrgia 10302 Cetr ". O'Reilly:,

On Santember 11, 1170 a renort es nW uM?- t"e crevisions of 10f ED:lO. F l ei conce nin0 th* E'?-7ancv 9iesel Gace-1t p Fa.n Ico'i99 Systell.

?n-ine a review of acuiou rt speci'icitions ?qd t? suis 21uent an2 lysis of l ac ti nat:crole1 cal dat a, it ns di.ccvared th=t 26i $rt temo$rature cannes 4

exist 'Atch avceed t'? c-iqinel dasian limits of tha Fan Coolina System. This

  • r'ssititas t"1t se'sen11 ble'o oitch encl? chanc?s 8:e made to frsu-a t5-t the fin d-fva ? cit ccualinq ho-sorower limit of

'0" M.D. is not $xc??!?.

d uy,*uar, t"a Inergency Di ss'! ";enerater mst

e in ' suu-?i mo'a te n$k = th?

T'911'

'lV ? oitch C i

h nces.

3 T o ?li"linate this time censumnina orec??P a $nd the subsequ?nt 9'iv111 ability of the Eatarqancy Diasel rienerators, tbe manuf 2ctu-ar IFai-Sanks

  • 0-s'*) ss anoinea-ed 1 modification to tha cur-aqt 'an d*ive s52ft coupling that will increitse the f n driva shif t tars'ony! 193.? c3-rying cap 3* ility 'ren i

130 to ??O 4.P.

This vill allow tha Emerca9cv Diesal 'ienaretor,to ocerate throuohout the vea-at a fixed tim!* oitch 2nn'e wit 9c1' ovarlo3dinq the 'in driva shaft. T;ie modification involves tha addition of two 591ts to the currnnt 'our Sa't counlin i?sien.

This Intter is an inte 'm ?0-< day recort on !"is su? ject'an.!. finti r? port will he submitted when the coc-active,ct'en is r09019ta.

If W 1tior.al Information is recu! rad for your eviaw, clease 90tifv us.

Ve v trulv yours,

. d d h c. < < > '

/ /

o

/ /

/

/ n,.-f Sam O. 9riiun, -1.

Senior Vice 3resi'=nt Onwer St1tf on Encineerino and Construction

, cc: V.

V'ctor Stello, Director O" ice of Inspection 4 Enforcement

'Ar. Harold R. Denton. Directne

\\k Of' ice of Nuclear Reactor Reoistion 4p Q 7010160

~