Text
- _ _ _ _ -__________
-
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .
,
4
UNITED STATES
g g,
jg
o
NUCLEAR REGULATORY COMMisslON
[
~
g
REGION I
q
$
g
631 PARK AVENUE
2
KING OF PRUSSI A. PENNSYLVANIA 19404
%
,0
.....
Docket Nos. 50-352
50-353
Philadelphia Electric ' Company
ATTN: Mr. V. S. Boyer
Vice President
Engineering and Research
2301 Market Street
Philadelphia, Pennsylvania 19101
Subject:
Inspection Report 50-352/79-11; 50-353/79-10
Limerick
Gentlemen:
This refers to the inspection conducted by Mr. J. Mattia of this effm
on October 15-31 and November 1-15, 1979 of activities authorized by NE
License Nos. CPPR-106 and CPPR-107 at the Limerick Generating Station
Units 1 and 2, Limerick, Pennysivania and to the discussions of our
findings held by Mr. J. Mattia with Mr. Corcoran and others of your
staff at the conclusion of the inspection.
Areas examined during this inspection are described in the Office of
Inspection and Enforcement Inspection Report which is enclosed with this
lette"
Within these areas, the inspection consisted of selective
exam.. dions of procedures and representative records, interviews with
personnel, and observations by the inspector.
Based on the results of this inspection, it appears that certain of your
activities were not conducted in full compliance with NRC requirements,
as set forth in the Notice of Violation, enclosed herewith as Appendix
~
A.
These items of noncompliance have been categorized into the levels
as described in our correspondence to you dated December 31, 1974.
This
notice is sent to you pursuant to the provisions of Section 2.201..' the
NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office, within thirty (30)
days of your receipt of this notice, a written statement or explanation
in reply including:
(1) corrective steps which have been taken by you
and the results achieved; (2) corrective steps which will be taken to
avoid further items of noncompliance; and (3) the date when full compliance
will be achieved.
8004230 0 79
.
.
.
.
Philadelphia Electric Company
2
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part
2, Title 10, Code of Federal Regulations, a copy of this letter and the
-
enclosures will be placed in the NRC's Public Document Room.
If this
report contains any information that you (or your contractor) believe to
be proprietary, it is necessary that you make a written application
within 20 days to this office to withhold such information from public
disclosure. Any such application must be accompanied by an affidavit
executed by the owner of the information, which identifies the document
or part sought to be withheld, and which contains a statement of reasons
which addresses with specificity the items which will be considered by
the Commission as listed in subparagraph (b) (4) of Section 2.790.
The
infonnation sought to be withheld shall be incorporated as far as possible
into a separate part of the affidavit.
If we do not hear from you in
this regard within the specified period, the report will be placed in
the Public Document Room.
Should you have any questions concerning this inspection, we will be
pleased to discuss them with you.
Sincerely,
f
l Robert T. Carlson, Chief.
. = -
.
Reactor Construction and Engineering
Support Branch
Enclosures:
1.
Appendix A, Notice of Violation
2.
Office of Inspection and Enforcement Inspection
Report Number 352/79-11 and 353/79-10
,
,