ML19305C211

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 80-04, Securing of Threaded Locking Devices on Safety-Related Equipment. No Written Response Required
ML19305C211
Person / Time
Site: Hatch, Vogtle  
Issue date: 03/14/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: John Miller
GEORGIA POWER CO.
References
NUDOCS 8003260177
Download: ML19305C211 (2)


Text

t

/

'o, UNITED STATES 8

NUCLEAR REGULATORY COMMISSION n

g ae REGION 11 b[

0, 101 MARIETTA ST., N.W., SUITE 3100 o

ATLANTA, GEORGIA 30303 In Reply Refer To:

MR 1/ 1980 1

JPO:RII 50-321 50-366k UA Georgia Power Company Attn:

J. H. Miller, Jr.

Executive Vice President 270 Peachtree Street Atlanta, GA 30303 Gentlemen:

The enclosed Circular No. 80-04 is forwarded to you for information.

No written response is required.

Should you have any questions related to your understanding of the recommendations on this matter, please contact this office.

Sincerely,

]'

e James P. O'Reill-Director

Enclosures:

1.

IE Circular No. 80-04 2.

List of Recently Issued IE Circulars o

B003 200177 6

~

MAR 14198d Georgia Power Company.

cc w/ encl:

M. Manry, Plant Manager Po6t Office Box 442 Bax18y Georgia 31513 j

~

C. E.,Belflower Site QA Supervisor Post Office Box 442 Baxley, Georgia 31513 K. M. Gillespic Construction Project. Manager Post Office Box 282 Waynesboro, Georgia 30830 E. D. Groover QA Site Supervisor Post Office Box 282 Waynesboro, Georgia 30830 W. A. Widner, General Manager Nuclear Generation Georgia Power Company Post Office Box 4545 Atlanta, Georgia 30303 i

4 7'

4' b

(

ENCLOSURE 1 SSINS NO. 6830 Accession No.:

UNITED STATES 7912190662 NUCLEAR REGULATORY COMMISSIAN OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Circular No. 80-04 Date:

March 14, 1980 Page 1 of 3 SECURING OF THREADED LOCKING DEVICES ON SAFETY-RELATED EQUIPMENT Description of Circumstances:

In recent months, several licensee event reports have been submitted that address the inoperability of safety-related equipment caused by loosened threaded locking devices.

Some of the events are listed below:

MAIN STEAM CHECK VALVE HEX NUT LOCKING DEVICES, TURKEY POINT NO. 3 1.

REPORTABLE OCCURRENCE 250-79-31 (Oct. 22, 1979)

During a planned outage of Turkey Point Unit No. 3 on October 7, 1979, a two-inch internal diameter hex nut was discovered in the internals of a steam supply valve for a moisture separator-reheater.

Investigation revealed that the nut was missing from the disc stud of the 3A main steam The disc and disc stud were in the proper position and the check valve.

The 38 and 3C main steam check valves were valve was fully operable.

inspected and the disc stud, nut and locking washer were in place although some distress was noted on the 3C locking washer in that the tack welds on the locking pin had separated.

The licensee installed an improved locking device on the disc stud on each of the three main steam check valves.

The locking devica consists of a tab washer that is prevented from' rotating by a pin and by fingers that extended on either side of the valve arm; the tabs are bent up against two faces of the hex nut.

The main steam isolation valves (MSIV) have the same type of hex nut locking device.

The valves are Schutte and Koerting SK Type 828.

SLIPPAGE AND MISALIGNMENT OF VALVE LINKAGES, DAVIS-BESSE LICENSEE EVENT II.

REPORT NOS78-101 (Nov.1,1978),78-126 (Jan. 26,1979),79-068 (July 19,1979), and 79-098 (Oct. 30,1979) f two service water s tem These reports involve the inope valves and one component cooli declared inoperable because th missing or had loosened to the DUPLICATE DOCUMENT ment of the valve linkage. Th The supplier has provided the 1 Entire docurnent previously manual that defines the torque entered into system under:

used to retain the actuator li ano 7<;<7/.2.Ng(,6 A No. of pages: